Evidence map›Paper›PMID 33547658›Full record

ArticleMagnetic resonance in medicine2021

A phantom study comparing radial trajectories for accelerated cardiac 4D flow MRI against a particle imaging velocimetry reference.

Philip A Corrado, Rafael Medero, Kevin M Johnson, Christopher J François, Alejandro Roldán-Alzate, Oliver Wieben

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Clinical Applications of 4D Flow MRI in the Portal Venous System.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022
    Review
  4. Sildenafil administration improves right ventricular function on 4D flow MRI in young adults born premature.American journal of physiology. Heart and circulatory physiology · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Philip A CorradoDepartment of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.ORCID 0000-0002-1510-8247
Rafael MederoDepartment of Mechanical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Kevin M JohnsonDepartments of Medical Physics and Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Christopher J FrançoisDepartment of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Alejandro Roldán-AlzateDepartments of Mechanical and Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Oliver WiebenDepartments of Medical Physics and Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.

Funding

4D Flow Cardiac Magnetic Resonance FOR Post Myocardial Infarction left ventricular thrombusF31HL144020 · NHLBI · UNIVERSITY OF WISCONSIN-MADISON · PI CORRADO, PHILIP ANGELO · 2019 to 2021
$72k
NHLBI NIH HHS F31 HL144020
6 · The paper itself

Abstract

purposeRadial sampling is one method to accelerate 4D flow MRI acquisition, making feasible dual-velocity encoding (Venc) assessment of slow flow in the left ventricle (LV). Here, two radial trajectories are compared in vitro for this application: 3D radial (phase-contrast vastly undersampled isotropic projection, PC-VIPR) versus stack of stars (phase-contrast stack of stars, PC-SOS), with benchtop particle imaging velocimetry (PIV) serving as a reference standard.

methodsThe study contained three steps: (1) Construction of an MRI- and PIV-compatible LV model from a healthy adult's CT images. (2) In vitro PIV using a pulsatile flow pump. (3) In vitro dual-Venc 4D flow MRI using PC-VIPR and PC-SOS (two repeat experiments). Each MR image set was retrospectively undersampled to five effective scan durations and compared with the PIV reference. The root-mean-square velocity vector difference (RMSE) between MRI and PIV images was compared, along with kinetic energy (KE) and wall shear stress (WSS).

resultsRMSE increased as scan time decreased for both MR acquisitions. RMSE was 3% lower in PC-SOS images than PC-VIPR images in 30-min scans (3.8 vs. 3.9 cm/s) but 98% higher in 2.5-min scans (9.5 vs. 4.8 cm/s). PIV intrasession repeatability showed a RMSE of 4.4 cm/s, reflecting beat-to-beat flow variation, while MRI had intersession RMSEs of 3.8/3.5 cm/s for VIPR/SOS, respectively. Speed, KE, and WSS were overestimated voxel-wise in 30-min MRI scans relative to PIV by 0.4/0.3 cm/s, 0.2/0.1 μJ/mL, and 36/43 mPa, respectively, for VIPR/SOS.

conclusionsPIV is feasible for application-specific 4D flow MRI protocol optimization. PC-VIPR is better-suited to dual-Venc LV imaging with short scan times.

Indexed as

Imaging, Three-DimensionalMagnetic Resonance ImagingBlood Flow VelocityReproducibility of ResultsRetrospective StudiesRheologydual-Vencflownon-cartesianphantomradialvalidation