Evidence map›Paper›PMID 33547387›Full record

ArticleCommunications biology2021

Second-generation lung-on-a-chip with an array of stretchable alveoli made with a biological membrane.

Pauline Zamprogno, Simon Wüthrich, Sven Achenbach, Giuditta Thoma, Janick D Stucki, Nina Hobi, Nicole Schneider-Daum, Claus-Michael Lehr, Hanno Huwer, Thomas Geiser and 2 more

Abstract read
In one paragraph

Article in Communications biology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 158 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
158citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

158 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Review
  10. Review
  11. New developments and applications of human organoids.Nature reviews. Molecular cell biology · 2026
    Review
  12. Article
  13. Review
  14. Review
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review

98 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Pauline ZamprognoOrgans-on-Chip Technologies Laboratory, ARTORG Center, University of Bern, Bern, Switzerland.
Simon WüthrichOrgans-on-Chip Technologies Laboratory, ARTORG Center, University of Bern, Bern, Switzerland.
Sven AchenbachOrgans-on-Chip Technologies Laboratory, ARTORG Center, University of Bern, Bern, Switzerland.ORCID http://orcid.org/0000-0002-0501-7261
Giuditta ThomaOrgans-on-Chip Technologies Laboratory, ARTORG Center, University of Bern, Bern, Switzerland.
Janick D StuckiOrgans-on-Chip Technologies Laboratory, ARTORG Center, University of Bern, Bern, Switzerland.
Nina HobiOrgans-on-Chip Technologies Laboratory, ARTORG Center, University of Bern, Bern, Switzerland.
Nicole Schneider-DaumDrug Delivery (DDEL), Helmholtz-Institute for Pharmaceutical Research Saarland (HIPS), Saarbrücken, Germany.
Claus-Michael LehrDrug Delivery (DDEL), Helmholtz-Institute for Pharmaceutical Research Saarland (HIPS), Saarbrücken, Germany.ORCID http://orcid.org/0000-0002-5864-8462
Hanno HuwerSHG Clinics, Department of Cardiothoracic Surgery, Völklingen Heart Center, Völklingen, Germany.
Thomas GeiserDepartment of Pulmonary Medicine, University Hospital of Bern, Bern, Switzerland.
Ralph A SchmidDepartment of General Thoracic Surgery, University Hospital of Bern, Bern, Switzerland.
Olivier T GuenatOrgans-on-Chip Technologies Laboratory, ARTORG Center, University of Bern, Bern, Switzerland. olivier.guenat@artorg.unibe.ch.ORCID http://orcid.org/0000-0003-1103-9712

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The air-blood barrier with its complex architecture and dynamic environment is difficult to mimic in vitro. Lung-on-a-chips enable mimicking the breathing movements using a thin, stretchable PDMS membrane. However, they fail to reproduce the characteristic alveoli network as well as the biochemical and physical properties of the alveolar basal membrane. Here, we present a lung-on-a-chip, based on a biological, stretchable and biodegradable membrane made of collagen and elastin, that emulates an array of tiny alveoli with in vivo-like dimensions. This membrane outperforms PDMS in many ways: it does not absorb rhodamine-B, is biodegradable, is created by a simple method, and can easily be tuned to modify its thickness, composition and stiffness. The air-blood barrier is reconstituted using primary lung alveolar epithelial cells from patients and primary lung endothelial cells. Typical alveolar epithelial cell markers are expressed, while the barrier properties are preserved for up to 3 weeks.

Indexed as

Lab-On-A-Chip DevicesMembranes, ArtificialAlveolar Epithelial CellsBlood-Air BarrierCell CommunicationCell Membrane PermeabilityCoculture TechniquesElasticityHumansLungMicrotechnologyPrimary Cell CulturePulmonary AlveoliStress, MechanicalTissue EngineeringTissue ScaffoldsMembranes, Artificial

Identifiers

PMID33547387
PMCPMC7864995

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.