Evidence map›Paper›PMID 33547081›Full record

ArticleScience advances2021

Parallel, linear, and subnanometric 3D tracking of microparticles with Stereo Darkfield Interferometry.

Martin Rieu, Thibault Vieille, Gaël Radou, Raphaël Jeanneret, Nadia Ruiz-Gutierrez, Bertrand Ducos, Jean-François Allemand, Vincent Croquette

Abstract read
In one paragraph

Article in Science advances, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Tuning the stability of DNA tetrahedra with base-stacking interactions.bioRxiv : the preprint server for biology · 2024
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Martin RieuLaboratoire de Physique de L'Ecole Normale Supérieure de Paris, CNRS, ENS, Université PSL, Sorbonne Université, Université de Paris, 75005 Paris, France.ORCID http://orcid.org/0000-0001-5371-0928
Thibault VieilleLaboratoire de Physique de L'Ecole Normale Supérieure de Paris, CNRS, ENS, Université PSL, Sorbonne Université, Université de Paris, 75005 Paris, France.ORCID http://orcid.org/0000-0001-8689-3935
Gaël RadouLaboratoire de Physique de L'Ecole Normale Supérieure de Paris, CNRS, ENS, Université PSL, Sorbonne Université, Université de Paris, 75005 Paris, France.
Raphaël JeanneretLaboratoire de Physique de L'Ecole Normale Supérieure de Paris, CNRS, ENS, Université PSL, Sorbonne Université, Université de Paris, 75005 Paris, France.ORCID http://orcid.org/0000-0002-9444-9129
Nadia Ruiz-GutierrezInstitut de Biologie de l'Ecole Normale Supérieure (IBENS), Ecole Normale Supérieure, CNRS, INSERM, Université PSL, 75005 Paris, France.ORCID http://orcid.org/0000-0002-5614-1270
Bertrand DucosLaboratoire de Physique de L'Ecole Normale Supérieure de Paris, CNRS, ENS, Université PSL, Sorbonne Université, Université de Paris, 75005 Paris, France.ORCID http://orcid.org/0000-0002-5322-1339
Jean-François AllemandLaboratoire de Physique de L'Ecole Normale Supérieure de Paris, CNRS, ENS, Université PSL, Sorbonne Université, Université de Paris, 75005 Paris, France.ORCID http://orcid.org/0000-0001-7496-0977
Vincent CroquetteLaboratoire de Physique de L'Ecole Normale Supérieure de Paris, CNRS, ENS, Université PSL, Sorbonne Université, Université de Paris, 75005 Paris, France. vincent.croquette@espci.psl.eu.ORCID http://orcid.org/0000-0003-1400-0039

Funding

European Research Council 267862
6 · The paper itself

Abstract

While crucial for force spectroscopists and microbiologists, three-dimensional (3D) particle tracking suffers from either poor precision, complex calibration, or the need of expensive hardware, preventing its massive adoption. We introduce a new technique, based on a simple piece of cardboard inserted in the objective focal plane, that enables simple 3D tracking of dilute microparticles while offering subnanometer frame-to-frame precision in all directions. Its linearity alleviates calibration procedures, while the interferometric pattern enhances precision. We illustrate its utility in single-molecule force spectroscopy and single-algae motility analysis. As with any technique based on back focal plane engineering, it may be directly embedded in a commercial objective, providing a means to convert any preexisting optical setup in a 3D tracking system. Thanks to its precision, its simplicity, and its versatility, we envision that the technique has the potential to enhance the spreading of high-precision and high-throughput 3D tracking.

Identifiers

PMID33547081
PMCPMC7864575

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.