Evidence map›Paper›PMID 33546403›Full record

ArticleMembranes2021

Effect of Temperature and Flow Rate on the Cell-Free Area in the Microfluidic Channel.

Angeles Ivón Rodríguez-Villarreal, Manuel Carmona-Flores, Jordi Colomer-Farrarons

Abstract read
In one paragraph

Article in Membranes, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Angeles Ivón Rodríguez-VillarrealDepartment of Electronics and Biomedical Engineering, Faculty of Physics, University of Barcelona, 08028 Barcelona, Spain.
Manuel Carmona-FloresDepartment of Electronics and Biomedical Engineering, Faculty of Physics, University of Barcelona, 08028 Barcelona, Spain.
Jordi Colomer-FarraronsDepartment of Electronics and Biomedical Engineering, Faculty of Physics, University of Barcelona, 08028 Barcelona, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Blood cell manipulation in microdevices is an interesting task for the separation of particles, by their size, density, or to remove them from the buffer, in which they are suspended, for further analysis, and more. This study highlights the cell-free area (CFA) widening based on experimental results of red blood cell (RBC) flow, suspended in a microfluidic device, while temperature and flow rate incrementally modify RBC response within the microflow. Studies of human red blood cell flow, at a concentration of 20%, suspended in its autologous plasma and phosphate-buffered saline (PBS) buffer, were carried out at a wide flow rate, varying between 10 and 230 μL/min and a temperature range of 23 °C to 50 °C. The plotted measures show an increment in a CFA near the channel wall due to cell flow inertia after a constricted channel, which becomes more significant as temperature and flow rate increase. The temperature increment widened the CFA up to three times. In comparison, flow rate increment increased the CFA up to 20 times in PBS and 11 times in plasma.

Indexed as

blood flowblood plasma separationcell-free areamicrodevicemicrofluidics

Identifiers

PMID33546403
PMCPMC7913562

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.