Evidence map›Paper›PMID 33544197›Full record

ArticleClinical oral investigations2021

Artefacts at different distances from titanium and zirconia implants in cone-beam computed tomography: effect of tube current and metal artefact reduction.

Arthur Xavier Maseti Mancini, Matheus Urias Cruz Santos, Hugo Gaêta-Araujo, Camila Tirapelli, Ruben Pauwels, Christiano Oliveira-Santos

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.8field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 3 countries.

Arthur Xavier Maseti ManciniDepartment of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil. arthur.mancini@usp.br.ORCID http://orcid.org/0000-0001-5443-8225
Matheus Urias Cruz SantosDepartment of Stomatology, Public Oral Health and Forensic Dentistry, Division of Oral Radiology, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil.
Hugo Gaêta-AraujoDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Piracicaba, São Paulo, 13414-903, Brazil.
Camila TirapelliDepartment of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil.
Ruben PauwelsMedical Physics & Quality Assessment, Department of Imaging & Pathology, Catholic University of Leuven, Leuven, Belgium and Aarhus Institute of Advanced Studies, Aarhus University, Høegh-Guldbergs Gade 6B, 8000, Aarhus, Denmark.
Christiano Oliveira-SantosDepartment of Stomatology, Public Oral Health and Forensic Dentistry, Division of Oral Radiology, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Av. Do Café, s/n, Ribeirao Preto, Sao Paulo, 14040-904, Brazil.
Universidade de São Paulo · BRAarhus University · DKUniversidade de Ribeirão Preto · BRUniversidade Estadual de Campinas (UNICAMP) · BR

Funding

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior 0001European Union Horizon 2020 Research and Innovation Programme 754513PUB-USP (Programa Unificado de Bolsas - University of São Paulo). 1016/2019Research Foundation - Flanders (FWO) V419619NSão Paulo Research Foundation (FAPESP) 2018/22952-7
6 · The paper itself

Abstract

objectivesTo evaluate the effect of cone-beam computed tomography (CBCT) tube current (mA) on the magnitude of artefacts at different distances from titanium or zirconia implants, with and without activation of a proprietary metal artefact reduction (MAR). MATERIAL AND

methodsHuman mandibles were scanned on an OP300 Maxio CBCT unit (Instrumentarium, Tuusula, Finland) before and after the installation of dental implants, with four different tube currents (4 mA, 6.3 mA, 8 mA and 10 mA), with and without activation of proprietary MAR. The effect of mA on the standard deviation (SD) of gray values and contrast to noise ratio (CNR) were assessed in regions of interest located 1.5 cm, 2.5 cm, and 3.5 cm from implants.

resultsIn the presence of titanium implants, a significant decrease in SD was found by increasing tube current from 4 mA to 6.3 mA or 8 mA. For zirconia implants, 8 mA yielded better results for all distances. MAR improved CNR in the presence of zirconia implants at all distances, whereas no differences were observed with the use of MAR for titanium implants.

conclusionIncreased tube current can improve overall image quality in the presence of implants, at all the distances tested. When a zirconia implant is present, such increase in mA should be higher in comparison to that for examinations with titanium implants. Activation of OP300 Maxio proprietary MAR improved image quality only among examinations with zirconia implants. CLINICAL RELEVANCE: Artefact-generating implants are common in the field of view of CBCT examinations. Optimal exposure parameters, such as tube current, ensure high image quality with lowest possible radiation exposure.

Indexed as

ArtifactsDental ImplantsCone-Beam Computed TomographyHumansTitaniumZirconiumDental ImplantsTitaniumZirconiumzirconium oxideArtefactsCone-beam computed tomographyTitanium implantsTube currentZirconia implants

Identifiers

PMID33544197
OpenAlexW3129007411

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.