Evidence map›Paper›PMID 33543063›Full record

ArticleArchives of rehabilitation research and clinical translation2020

Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device.

Clare Lodge, Diarmuid Tobin, Brian O'Rourke, Kristian Thorborg

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Archives of rehabilitation research and clinical translation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06460883 (Effects of Eccentric Banded Leg Curls Versus Eccentric Cable Leg Curls Exercises on Eccentric Knee-flexor Strength, Power and Endurance in Cricket Players), which is not on this map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
2.5field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06460883 nacompletednot on this mapstarted 2024, after this paper: background citation

Effects of Eccentric Banded Leg Curls Versus Eccentric Cable Leg Curls Exercises on Eccentric Knee-flexor Strength, Power and Endurance in Cricket Players

TypeinterventionalSponsorRiphah International UniversityRan2024 to 2025Enrolled28ConditionsHamstring Muscle, Muscle Strength, Treatment EfficacyArmseccentric cable leg curls, eccentric banded leg curls
3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 25 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. International journal of environmental research and public health · 2022
    Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Clare LodgeDepartment of Science and Health, Institute of Technology Carlow, Carlow, Ireland.
Diarmuid TobinDepartment of Science and Health, Institute of Technology Carlow, Carlow, Ireland.
Brian O'RourkeDepartment of Science and Health, Institute of Technology Carlow, Carlow, Ireland.
Kristian ThorborgFaculty of Health Sciences, Copenhagen University, Hvidovre, Denmark.
Institute of Technology Carlow · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo investigate the reliability and establish validity of a new eccentric hamstring strength measurement device.

designA randomized double-crossover trial with intraclass correlation coefficients to analyze the outcomes. Participants attended 4 sessions, 7 days apart. They were randomly allocated into 2 groups. Session 1 was a familiarization session for all participants on the new eccentric hamstring strength measurement device and isokinetic dynamometer. The following 3 sessions were used to measure knee flexor (hamstring) eccentric strength on the isokinetic dynamometer and a further test-retest measurement using the new eccentric hamstring strength measurement device.

settingInstitute of Technology Carlow, third level educational institution.

participantsMale intercollegiate field-sport players completed the trial (N=19). Participants were 21±2 years, weighed 78.6±4.6 kg, and were 179.6±6.4 cm in height.

interventionsN/A.

main outcome measuresPeak torque (Nm) was recorded by the isokinetic device, and peak force (N) was recorded by the new eccentric hamstring strength measurement device and used to test for significant interdevice correlations (>0.7). Intraclass correlation coefficients were calculated using the peak force recorded from 2 separate trials of the new eccentric hamstring strength measurement device.

resultsHigh test-retest reliability was observed from the new eccentric hamstring strength measurement device, intraclass coefficient (ICC)=.910 (confidence interval [CI], .76-.96) and .914 (CI, .78-.96) for left and right peak forces, respectively. Typical error of measurement between trials was calculated to be 14.65 and 17.29N for the left and right limbs, respectively. Minimum detectable change (MDC) was also calculated to be 40.62N (MDC%=14.68%) and 39.63N (MDC%=13.31%) for left and right limbs, respectively. The interdevice correlation showed good validity, ICC=.823 (CI, .58-.93) and .840 (CI, .58-.93) for left and right peak torque/forces, respectively.

conclusionsThe new eccentric hamstring strength measurement device is a reliable and valid device that provides an objective measurement of eccentric hamstring strength that may be used in combination with a comprehensive assessment to inform rehabilitation and management.

Indexed as

CI, confidence intervalClinical decision-makingCV, coefficient of varianceHamstring musclesICC, intraclass coefficientMDC, minimum detectable changeRehabilitation

Identifiers

PMID33543063
PMCPMC7853328
OpenAlexW2991179425

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.