Evidence map›Paper›PMID 33542892›Full record

ArticleChemElectroChem2020

Micromolded Carbon Paste Microelectrodes for Electrogenerated Chemiluminescent Detection on Microfluidic Devices.

Erin M Gross, Laura R Porter, Nicholas R Stukel, Emily R Lowry, Leah V Schaffer, Sai Sujana Maddipati, Dylan J Hoyt, Sarah E Stombaugh, Sarah R Peila, Charles S Henry

Abstract read
In one paragraph

Article in ChemElectroChem, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Erin M GrossDepartment of Chemistry, Creighton University, 2500 California Plaza, Omaha, NE 68178.
Laura R PorterDepartment of Chemistry, Creighton University, 2500 California Plaza, Omaha, NE 68178.
Nicholas R StukelDepartment of Chemistry, Creighton University, 2500 California Plaza, Omaha, NE 68178.
Emily R LowryDepartment of Chemistry, Creighton University, 2500 California Plaza, Omaha, NE 68178.
Leah V SchafferDepartment of Chemistry, Creighton University, 2500 California Plaza, Omaha, NE 68178.
Sai Sujana MaddipatiDepartment of Chemistry, Creighton University, 2500 California Plaza, Omaha, NE 68178.
Dylan J HoytDepartment of Chemistry, Creighton University, 2500 California Plaza, Omaha, NE 68178.
Sarah E StombaughDepartment of Chemistry, Creighton University, 2500 California Plaza, Omaha, NE 68178.
Sarah R PeilaDepartment of Chemistry, Creighton University, 2500 California Plaza, Omaha, NE 68178.
Charles S HenryDepartment of Chemistry, Colorado State University, Fort Collins, CO 80523.

Funding

UNMC Structural Biology CoreP20GM103427 · NIGMS · UNIVERSITY OF NEBRASKA MEDICAL CENTER · PI Heather Colleen Jensen-Smith · 2012 to 2026
$59.2M
NIGMS NIH HHS P20 GM103427
6 · The paper itself

Abstract

Micromolded carbon paste electrodes are easily fabricated, disposable, and can be integrated into microfluidic devices to fabricate inexpensive sensors and biosensors. In this work, carbon paste microelectrodes were fabricated in poly(dimethylsiloxane) using micromolding techniques and were coupled to a microfluidic channel to fabricate electrogenerated chemiluminescent (ECL) sensors. ECL was generated using both the tris(2,2'-bipyridyl)ruthenium(II)-tripropylamine system and the hydrogen peroxide and luminol system. For each of these ECL systems, the sensor fabrication method was optimized, along with key experimental parameters (applied voltage, solution flow rate, buffer species and luminol concentration). The limit of detection (S/N = 3) for TPrA was ~2.4 μM with a linear range of 10-100μM. For hydrogen peroxide the LOD was ~11 μM and the electrodes gave a linear response between 30 μM and 200 μM hydrogen peroxide. Electrodes containing glucose oxidase were fabricated using this new method, demonstrating that glucose could be indirectly detected via generation of hydrogen peroxide by the enzymatic reaction at the micromolded biosensor.

Indexed as

carbon electrodeselectrochemiluminescenceluminolmicrofluidicstris(2,2’-bipyridyl)ruthenium

Identifiers

PMID33542892
PMCPMC7853645

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.