Characterisation of Textile Embedded Electrodes for Use in a Neonatal Smart Mattress Electrocardiography System.

Henry Dore, Rodrigo Aviles-Espinosa, Zhenhua Luo, Oana Anton, Heike Rabe, Elizabeth Rendon-Morales

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.0field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 20 citations in OpenAlex.

  1. Review
  2. Article
  3. Unobtrusive Bed Monitor State of the Art.Sensors (Basel, Switzerland) · 2025
    Review
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Henry DoreRobotics and Mechatronics Systems Research Group, School of Engineering and Informatics, University of Sussex, Brighton BN1 9RH, UK.ORCID 0000-0003-3197-5209
Rodrigo Aviles-EspinosaRobotics and Mechatronics Systems Research Group, School of Engineering and Informatics, University of Sussex, Brighton BN1 9RH, UK.
Zhenhua LuoSchool of Water, Energy and Environment, Cranfield University, Bedford MK43 0AL, UK.ORCID 0000-0003-0766-6174
Oana AntonAcademic Department of Paediatrics, Royal Alexandra Children's Hospital Brighton, Brighton BN2 5BE, UK.
Heike RabeAcademic Department of Paediatrics, Royal Alexandra Children's Hospital Brighton, Brighton BN2 5BE, UK.
Elizabeth Rendon-MoralesRobotics and Mechatronics Systems Research Group, School of Engineering and Informatics, University of Sussex, Brighton BN1 9RH, UK.
University of Sussex · GBRoyal Alexandra Children's Hospital · GBCranfield University · GB

Funding

Engineering and Physical Sciences Research Council RES/0560/7386/004
6 · The paper itself

Abstract

Heart rate monitoring is the predominant quantitative health indicator of a newborn in the delivery room. A rapid and accurate heart rate measurement is vital during the first minutes after birth. Clinical recommendations suggest that electrocardiogram (ECG) monitoring should be widely adopted in the neonatal intensive care unit to reduce infant mortality and improve long term health outcomes in births that require intervention. Novel non-contact electrocardiogram sensors can reduce the time from birth to heart rate reading as well as providing unobtrusive and continuous monitoring during intervention. In this work we report the design and development of a solution to provide high resolution, real time electrocardiogram data to the clinicians within the delivery room using non-contact electric potential sensors embedded in a neonatal intensive care unit mattress. A real-time high-resolution electrocardiogram acquisition solution based on a low power embedded system was developed and textile embedded electrodes were fabricated and characterised. Proof of concept tests were carried out on simulated and human cardiac signals, producing electrocardiograms suitable for the calculation of heart rate having an accuracy within ±1 beat per minute using a test ECG signal, ECG recordings from a human volunteer with a correlation coefficient of ~ 87% proved accurate beat to beat morphology reproduction of the waveform without morphological alterations and a time from application to heart rate display below 6 s. This provides evidence that flexible non-contact textile-based electrodes can be embedded in wearable devices for assisting births through heart rate monitoring and serves as a proof of concept for a complete neonate electrocardiogram monitoring system.

Indexed as

BedsElectrocardiographyMonitoring, PhysiologicWearable Electronic DevicesElectrodesHumansInfant, NewbornTextileselectric potential sensorelectrocardiogramelectrodemedical devicestextilewearables

Identifiers

PMID33540669
PMCPMC7867279
OpenAlexW3128250315

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.