Evidence map›Paper›PMID 33539447›Full record

ArticlePloS one2021

Reliability and reproducibility of cardiac MRI quantification of peak exercise function with long-axis views.

Amy A Kirkham, Michelle V Goonasekera, Brenna C Mattiello, Justin G Grenier, Mark J Haykowsky, Richard B Thompson

Abstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. The future of CMR: All-in-one vs. real-time CMR (Part 2).Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Review
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Amy A KirkhamDepartment of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.ORCID 0000-0002-3847-1225
Michelle V GoonasekeraDepartment of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.
Brenna C MattielloFaculty of Kinesiology, Sport, and Recreation, University of Alberta, Edmonton, Alberta, Canada.
Justin G GrenierDepartment of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.ORCID 0000-0003-1937-1111
Mark J HaykowskyFaculty of Nursing, University of Alberta, Edmonton, Alberta, Canada.
Richard B ThompsonDepartment of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.ORCID 0000-0003-3319-4377

Funding

CIHR
6 · The paper itself

Abstract

The conventional approach to cardiac magnetic resonance (CMR) involving breath holds, electrocardiography-gating, and acquisition of a short-axis (SAX) image stack, introduces technical and logistical challenges for assessing exercise left ventricular (LV) function. Real-time, free-breathing CMR acquisition of long-axis (LAX) images overcomes these issues and also enables assessment of global longitudinal strain (GLS). We evaluated the reliability of a free-breathing LAX approach compared to the standard SAX approach and the reproducibility of free-breathing LAX. LV SAX (contiguous stack) and LAX (two-chamber and four-chamber) 3T CMR cine images were acquired four times within one scan in 32 women with cardiovascular risk factors (56±10 years, 28±4 kg/m2) as follows: 1) resting, gated-segmented, end-expiration breath-hold; 2) resting, real-time, free-breathing; 3) test-retest set of resting, real-time, free-breathing; 4) peak exercise (incremental-to-maximum, in-magnet, stepper test), real-time, free-breathing. A second scan was performed within one week in a subset (n = 5) to determine reproducibility of peak exercise measures. Reliability and agreement of the free-breathing LAX approach with the conventional SAX approach were assessed by intraclass correlation coefficient (ICC) and Bland-Altman plots, respectively. Normal control GLS reserve was also acquired in a separate set of 12 young, healthy control women (25±4 years, 22±2 kg/m2) for comparison. Comparisons of LV volumes and function among all techniques at rest had good-to-excellent reliability (ICC = 0.80-0.96), and excellent reliability between peak exercise free-breathing LAX and SAX evaluations (ICC = 0.92-0.96). Higher resting heart rates with free-breathing acquisitions compared to breath-hold (mean difference, limits of agreement: 5, 1-12 beats per minute) reduced reliability for cardiac output (ICC = 0.67-0.79). Reproducibility of the free-breathing LAX approach was good-to-excellent at rest and peak exercise (ICC = 0.74-0.99). GLS exercise reserve was impaired in older women at cardiovascular risk compared to young healthy women (-4.7±2.3% vs -7.4±2.1%, p = 0.001). Real-time, free-breathing CMR with LAX evaluation provides a reliable and reproducible method to assess rest and peak exercise cardiac function, including GLS.

Indexed as

ExerciseMagnetic Resonance ImagingAdultFemaleHeartHumansImage Processing, Computer-AssistedMaleMiddle AgedReproducibility of ResultsVentricular Function, Left

Identifiers

PMID33539447
PMCPMC7861545

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.