Evidence map›Paper›PMID 33539441›Full record

ArticlePloS one2021

Usefulness of the MALDI-TOF MS technology with membrane filter protocol for the rapid identification of microorganisms in perioperative drainage fluids of hepatobiliary pancreatic surgery.

Kazuyuki Sogawa, Shigetsugu Takano, Takayuki Ishige, Hideyuki Yoshitomi, Shingo Kagawa, Katsunori Furukawa, Tsukasa Takayashiki, Satoshi Kuboki, Fumio Nomura, Masayuki Ohtsuka

Abstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Kazuyuki SogawaDepartment of Biochemistry, School of Life and Environmental Science, Azabu University, Kanagawa, Japan.
Shigetsugu TakanoDepartment of General Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.ORCID 0000-0002-6495-0422
Takayuki IshigeDivision of Laboratory Medicine, Chiba University Hospital, Chiba, Japan.
Hideyuki YoshitomiDepartment of General Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.
Shingo KagawaDepartment of General Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.
Katsunori FurukawaDepartment of General Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.
Tsukasa TakayashikiDepartment of General Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.
Satoshi KubokiDepartment of General Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.
Fumio NomuraDivisions of Clinical Mass Spectrometry and Clinical Genetics, Chiba University Hospital, Chiba, Japan.
Masayuki OhtsukaDepartment of General Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Surgical site infections (SSIs) are significant and frequent perioperative complications, occurring due to the contamination of the surgical site. The late detection of SSIs, especially organ/space SSIs which are the more difficult to treat, often leads to severe complications. An effective method that can identify bacteria with a high accuracy, leading to the early detection of organ/space SSIs, is needed. Ninety-eight drainage fluid samples obtained from 22 patients with hepatobiliary pancreatic disease were analyzed to identify microorganisms using matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) with a new membrane filtration protocol and rapid BACpro® pretreatment compared to sole rapid BACpro® pretreatment. The levels of detail of rapid BACpro® pretreatment with or without filtration were also evaluated for the accuracy of bacterial identification. We found that reliable scores for E. coli and E. faecalis were obtained by inoculation with 1.0 × 104 CFU/ml after preparation of the membrane filter with rapid BACpro®, indicating approximately 10-folds more sensitive compared to sole rapid BACpro® pretreatment in drainage fluid specimens. Among 60 bacterial positive colonies in drainage fluid specimens, the MALDI-TOF MS and the membrane filtration with rapid BACpro® identified 53 isolates (88.3%) with a significantly higher accuracy, compared to 25 isolates in the rapid BACpro® pretreatment group (41.7%) (p < 0.001). Among the 78 strains, 14 enteric Gram-negative bacteria (93.0%) and 55 Gram-positive cocci (87.3%) were correctly identified by the membrane filtration with rapid BACpro® with a high reliability. This novel protocol could identify bacterial species within 30 min, at $2-$3 per sample, thus leading to cost and time savings. MALDI-TOF MS with membrane filter and rapid BACpro® is a quick and reliable method for bacterial identification in drainage fluids. The shortened analysis time will enable earlier selection of suitable antibiotics for treatment of organ/space SSIs to improve patients' outcomes.

Indexed as

DrainageFiltrationMembranes, ArtificialPerioperative PeriodSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationAgedAnimalsBacterial Typing TechniquesFemaleHepatopancreasHumansMaleTime FactorsMembranes, Artificial

Identifiers

PMID33539441
PMCPMC7861402

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.