ArticleAnnals of biomedical engineering2021
In Vivo Intravascular Pacing Using a Wireless Microscale Stimulator.
Article in Annals of biomedical engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 9 citations in OpenAlex.
- Advances in Machine Learning for Wearable Sensors.ACS nano · 2024Review
- A PARYLENE-BASED MEMS INTRAVASCULAR IMPLANT FOR WIRELESS CARDIAC PACING.Proceedings. IEEE International Conference on Micro Electro Mechanical Systems · 2024Article
- Nanostructured wearable electrochemical and biosensor towards healthcare management: a review.RSC advances · 2023Review
- New Era of Electroceuticals: Clinically Driven Smart Implantable Electronic Devices Moving towards Precision Therapy.Micromachines · 2022Review
- Miniaturized wireless gastric pacing via inductive power transfer with non-invasive monitoring using cutaneous Electrogastrography.Bioelectronic medicine · 2021Article
- Wearable Biosensors for Non-Invasive Sweat Diagnostics.Biosensors · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors at 3 institutions in 1 country.
Funding
Abstract
Millions of patients worldwide are implanted with permanent pacemakers for the treatment of cardiac arrhythmias and conduction disorders. The increased use of these devices has established a growing clinical need to mitigate associated complications. Pacemaker leads, in particular, present the primary risks in most implants. While wireless power transfer holds great promise in eliminating implantable device leads, anatomical constraints limit efficient wireless transmission over the necessary operational range. We thereby developed a transmitter-centered control system for wireless power transfer with sufficient power for continuous cardiac pacing. Device safety was validated using a computational model of the system within an MRI-based anatomical model. The pacer was then fabricated to meet the acute constraints of the anterior cardiac vein (ACV) to enable intravascular deployment while maintaining power efficiency. Our computational model revealed the wireless system to operate at > 50 times below the tissue energy absorption safety criteria. We further demonstrated the capacity for ex vivo pacing of pig hearts at 60 beats per minute (BPM) and in vivo pacing at 120 BPM following pacer deployment in the ACV. This work thus established the capacity for wireless intravascular pacing with the potential to eliminate complications associated with current lead-based deep tissue implants.