Evidence map›Paper›PMID 33536505›Full record

ArticleScientific reports2021

Label free, electric field mediated ultrasensitive electrochemical point-of-care device for CEA detection.

B Chakraborty, A Das, N Mandal, N Samanta, N Das, C Roy Chaudhuri

Open access · goldAbstract readValidation Study
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

B ChakrabortyDepartment of Electronics and Telecommunication Engineering, Indian Institute of Engineering Science and Technology, Shibpur, West Bengal, 711103, India.
A DasDepartment of Electronics and Telecommunication Engineering, Indian Institute of Engineering Science and Technology, Shibpur, West Bengal, 711103, India.
N MandalSchool of Electrical Sciences, Indian Institute of Technology Goa, Ponda, 403401, Goa, India.
N SamantaDepartment of Electronics and Communication Engineering, Techno India University, Sector V, Kolkata, 700091, West Bengal, India.
N DasDepartment of Electronics and Communication Engineering, KL University, Green Fields, Vaddeswaram, Andhra Pradesh, 522502, India.
C Roy ChaudhuriDepartment of Electronics and Telecommunication Engineering, Indian Institute of Engineering Science and Technology, Shibpur, West Bengal, 711103, India. chirosreepram@gmail.com.
Indian Institute of Engineering Science and Technology, Shibpur · INIndian Institute of Technology Goa · INKoneru Lakshmaiah Education Foundation · INTechno India University · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Developing point-of-care (PoC) diagnostic platforms for carcinoembryonic antigen detection is essential. However, thefew implementations of transferring the signal amplification strategies in electrochemical sensing on paper-based platforms are not satisfactory in terms of detection limit (LOD). In the quest for pushing down LOD, majority of the research has been targeted towards development of improved nanostructured substrates for entrapping more analyte molecules and augmenting the electron transfer rate to the working electrode. But, such approaches have reached saturation. This paper focuses on enhancing the mass transport of the analyte towards the sensor surface through the application of an electric field, in graphene-ZnO nanorods heterostructure. These hybrid nanostructures have been deposited on flexible polyethylene terephthalate substrates with screen printed electrodes for PoC application. The ZnO nanorods have been functionalized with aptamers and the working sensor has been integrated with smartphone interfaced indigenously developed low cost potentiostat. The performance of the system, requiring only 50 µl analyte has been evaluated using electrochemical impedance spectroscopy and validated against commercially available ELISA kit. Limit of detection of 1 fg/ml in human serum with 6.5% coefficient of variation has been demonstrated, which is more than three orders of magnitude lower than the existing attempts on PoC device.

Indexed as

Point-of-Care SystemsPoint-of-Care TestingAptamers, NucleotideCarcinoembryonic AntigenElectrochemical TechniquesGraphiteHumansLimit of DetectionNanotubesZinc OxideAptamers, NucleotideCarcinoembryonic AntigenGraphiteZinc Oxide

Identifiers

PMID33536505
PMCPMC7859218
OpenAlexW3127045832

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.