Evidence map›Paper›PMID 33536401›Full record

ArticleMagnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine2021

Investigating the Image Quality and Utility of Synthetic MRI in the Breast.

Tomoyuki Fujioka, Mio Mori, Jun Oyama, Kazunori Kubota, Emi Yamaga, Yuka Yashima, Leona Katsuta, Kyoko Nomura, Miyako Nara, Goshi Oda and 2 more

Open access · diamondAbstract read
In one paragraph

Article in Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 2 institutions in 1 country.

Tomoyuki FujiokaDepartment of Diagnostic Radiology, Tokyo Medical and Dental University.
Mio MoriDepartment of Diagnostic Radiology, Tokyo Medical and Dental University.
Jun OyamaDepartment of Diagnostic Radiology, Tokyo Medical and Dental University.
Kazunori KubotaDepartment of Diagnostic Radiology, Tokyo Medical and Dental University.
Emi YamagaDepartment of Diagnostic Radiology, Tokyo Medical and Dental University.
Yuka YashimaDepartment of Diagnostic Radiology, Tokyo Medical and Dental University.
Leona KatsutaDepartment of Diagnostic Radiology, Tokyo Medical and Dental University.
Kyoko NomuraDepartment of Diagnostic Radiology, Tokyo Medical and Dental University.
Miyako NaraDepartment of Diagnostic Radiology, Tokyo Medical and Dental University.
Goshi OdaDepartment of Surgery, Breast Surgery, Tokyo Medical and Dental University.
Tsuyoshi NakagawaDepartment of Surgery, Breast Surgery, Tokyo Medical and Dental University.
Ukihide TateishiDepartment of Diagnostic Radiology, Tokyo Medical and Dental University.
Tokyo Medical and Dental University · JPTokyo Metropolitan Komagome Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeSynthetic MRI reconstructs multiple sequences in a single acquisition. In the present study, we aimed to compare the image quality and utility of synthetic MRI with that of conventional MRI in the breast.

methodsWe retrospectively collected the imaging data of 37 women (mean age: 55.1 years; range: 20-78 years) who had undergone both synthetic and conventional MRI of T2-weighted, T1-weighted, and fat-suppressed (FS)-T2-weighted images. Two independent breast radiologists evaluated the overall image quality, anatomical sharpness, contrast between tissues, image homogeneity, and presence of artifacts of synthetic and conventional MRI on a 5-point scale (5 = very good to 1 = very poor). The interobserver agreement between the radiologists was evaluated using weighted kappa.

resultsFor synthetic MRI, the acquisition time was 3 min 28 s. On the 5-point scale evaluation of overall image quality, although the scores of synthetic FS-T2-weighted images (4.01 ± 0.56) were lower than that of conventional images (4.95 ± 0.23; P < 0.001), the scores of synthetic T1- and T2-weighted images (4.95 ± 0.23 and 4.97 ± 0.16) were comparable with those of conventional images (4.92 ± 0.27 and 4.97 ± 0.16; P = 0.484 and 1.000, respectively). The kappa coefficient of conventional MRI was fair (0.53; P < 0.001), and that of conventional MRI was fair (0.46; P < 0.001).

conclusionThe image quality of synthetic T1- and T2-weighted images was similar to that of conventional images and diagnostically acceptable, whereas the quality of synthetic T2-weighted FS images was inferior to conventional images. Although synthetic MRI images of the breast have the potential to provide efficient image diagnosis, further validation and improvement are required for clinical application.

Indexed as

BreastMagnetic Resonance ImagingArtifactsFemaleHumansMiddle AgedRetrospective Studiesbreastbreast cancermagnetic resonance imagingsynthetic magnetic resonance imaging

Identifiers

PMID33536401
PMCPMC8922358
OpenAlexW3126474523

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.