Evidence map›Paper›PMID 33533946›Full record

ArticleNeuroradiology2021

Reliability and accuracy of 3-mm and 2-mm maximum intensity projection CT angiography to detect intracranial large vessel occlusion in patients with acute anterior cerebral circulation stroke.

Bram A C M Fasen, Rob A P Borghans, Roeland J J Heijboer, Frans-Jan H Hulsmans, Robert M Kwee

Abstract read
PubMed Publisher
In one paragraph

Article in Neuroradiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Encoding 3D information in 2D feature maps for brain CT-Angiography.Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Bram A C M FasenDepartment of Radiology, Zuyderland Medical Center, Heerlen/Sittard/Geleen, The Netherlands.
Rob A P BorghansDepartment of Radiology, Zuyderland Medical Center, Heerlen/Sittard/Geleen, The Netherlands.
Roeland J J HeijboerDepartment of Radiology, Zuyderland Medical Center, Heerlen/Sittard/Geleen, The Netherlands.
Frans-Jan H HulsmansDepartment of Radiology, Zuyderland Medical Center, Heerlen/Sittard/Geleen, The Netherlands.
Robert M KweeDepartment of Radiology, Zuyderland Medical Center, Heerlen/Sittard/Geleen, The Netherlands. rmkwee@gmail.com.ORCID http://orcid.org/0000-0001-7760-867X
Zuyderland Medisch Centrum · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the reliability and accuracy of thick maximum intensity projection (MIP) CTA images to detect large-vessel occlusion (LVO) in the anterior circulation in patients with acute stroke.

methodsA total of 140 acute stroke patients (41 with and 99 without LVO) were evaluated by two neuroradiologists for LVO using axial 3-mm and 2-mm MIPs.

resultsInterobserver agreement was substantial using 3-mm MIPs (ĸ = 0.67) and almost perfect using 2-mm MIPs (ĸ = 0.82). Using 3-mm MIPs, sensitivities were 80.5% and 68.3%, with specificities of 98.0% and 96.0%. Using 2-mm MIPs, sensitivities were 82.9% and 73.2%, with specificities of 98.0% and 99.0%. Sensitivity and specificity of 3 mm and 2 mm MIPs were not statistically significantly different (P ≥ 0.375). The majority of LVOs in the distal intracranial carotid artery, and/or M1-segment were correctly identified: 96.0% (observer 1, 3-mm MIPs), 88.0% (observer 2, 3-mm MIPs), 96.0% (observer 1, 2-mm MIPs), and 96.0% (observer 2, 2 mm MIPs). Using 3-mm MIP images, observers 1 and 2 missed 7/15 (46.7%) and 9/15 (60.0%) of isolated M2-segment occlusions, respectively. Using 2-mm MIP images, observers 1 and 2 missed 5/15 (33.3%) and 6/15 (40.0%) of isolated M2-segment occlusions, respectively.

conclusionThick (2-3 mm) axial MIPs are not useful to detect proximal LVO in the anterior circulation.

Indexed as

Computed Tomography AngiographyStrokeCerebral AngiographyCerebrovascular CirculationHumansReproducibility of ResultsAngiographyComputed tomographyMethodsSensitivitySpecificityStroke

Identifiers

PMID33533946
OpenAlexW3127787544

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.