ArticleSkeletal radiology2021
Limitations of dual-energy CT in the detection of monosodium urate deposition in dense liquid tophi and calcified tophi.
Article in Skeletal radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 27 citations in OpenAlex.
- Axial gout diagnosed by dual-energy CT in a young normouricaemic man with recurrent nephrolithiasis: a case-based review.Rheumatology international · 2026Review
- Kiesselbach's area nasal septal gouty tophus with an integrated "3 + 2" diagnostic algorithm: a case report.Journal of medical case reports · 2025Article
- Prediction of Monosodium Urate Crystal Deposits in the First Metatarsophalangeal Joint Using a Decision Tree ModelCurrent medical imaging · 2025Article
- Material decomposition approaches for monosodium urate (MSU) quantification in gouty arthritis: a (bio)phantom study.European radiology experimental · 2024Article
- What to Expect (and What Not) from Dual-Energy CT Imaging Now and in the Future?Journal of imaging · 2024Review
- Virtual noncontrast images reveal gouty tophi in contrast-enhanced dual-energy CT: a phantom study.European radiology experimental · 2024Article
- Updates on the Applications of Spectral Computed Tomography for Musculoskeletal Imaging.Diagnostics (Basel, Switzerland) · 2024Review
- Impact of Dual-Energy Computed Tomography (DECT) Postprocessing Protocols on Detection of Monosodium Urate (MSU) Deposits in Foot Tendons of Cadavers.Diagnostics (Basel, Switzerland) · 2023Article
- Musculoskeletal Ultrasound in Monitoring the Efficacy of Gout: A Prospective Study Based on Tophus and Double Contour SignBalkan medical journal · 2023Article
- Prevalence of Monosodium Urate (MSU) Deposits in Cadavers Detected by Dual-Energy Computed Tomography (DECT).Diagnostics (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 6 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveDual-energy CT (DECT) detection of monosodium urate (MSU) crystal deposition has demonstrated good sensitivity and specificity in patients with established gout. However, limitations have been reported with early disease and with low urate burden. We aimed to study the performance of DECT in the detection and quantification of MSU deposition in solid and liquid tophi. MATERIALS AND
methodsPatient-derived solid and liquid tophi, suspensions of commercial synthetic, and in-house synthetic MSU crystals were prepared at varying concentrations. DECT was performed at 80 kVp and 150 kVp, and post-processed using Syngo Via gout software (Siemens) that color-coded urate and cortical bone as green and purple, respectively. DECT findings were correlated with ultrasound and microscopic findings. The protocol was reviewed by IRB and considered a non-human subject research.
resultsDECT did not detect urate deposition in either patient-derived liquid tophi or in-house synthetic crystals at any concentration. Lowering the post-processing minimum threshold increased the detection of in-house synthetic crystals but did not change the detection of patient-derived liquid tophi. Areas of calcium-rich purple color-coded regions, masking detection of urate, within the solid tophi and surrounding liquid tophi were noted on DECT. Histology showed co-presence of calcium along with MSU deposition in these.
conclusionThis study illustrates important limitations of DECT for liquid tophi due to subthreshold CT attenuation and for calcified tophi due to the obscuration of urate by calcium. Urate may be either undetectable or underestimated by DECT when these conditions are present.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.