Evidence map›Paper›PMID 33531034›Full record

ArticleEuropean journal of medical research2021

Comparable results using 2.0-mm vs. 3.5-mm screw augmentation in midshaft clavicle fractures: a 10-year experience.

M Wurm, M Zyskowski, F Greve, A Gersing, P Biberthaler, C Kirchhoff

Abstract read
In one paragraph

Article in European journal of medical research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

M WurmDepartment of Trauma Surgery, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Strasse 22, 81675, Munich, Germany.ORCID https://orcid.org/0000-0001-6114-3281
M ZyskowskiDepartment of Trauma Surgery, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Strasse 22, 81675, Munich, Germany.
F GreveDepartment of Trauma Surgery, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Strasse 22, 81675, Munich, Germany.
A GersingDepartment of Radiology, Klinikum Rechts Der Isar, Technical University of Munich, Munich, Germany.
P BiberthalerDepartment of Trauma Surgery, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Strasse 22, 81675, Munich, Germany.
C KirchhoffDepartment of Trauma Surgery, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Strasse 22, 81675, Munich, Germany. chlodwig.kirchhoff@mri.tum.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAbsence of cortical alignment in wedge-shaped and multifragmentary fractures (Fx) results in decreased fixation stability. The aim of this study was to compare the outcome using 2.0- vs. 3.5-mm screws for open reduction and internal fixation (ORIF) in dislocated, wedge-shaped or fragmentary midshaft clavicle fractures. MATERIALS AND

methodsPatients suffering from AO/OTA 15 2.A-C midshaft clavicle fractures were operatively treated between 2008 and 2018. 2.0- or 3.5-mm cortical screws were used to restore anatomic alignment in dislocated, wedge-shaped and fragmentary clavicle fractures. Data of radiologic outcome were collected until fracture consolidation was identified.

results80 consecutive patients with a mean age of 44.5 ± 16.3 years, who were operatively treated for dislocated midshaft clavicle fractures were enrolled. 40 patients were treated using 2.0-mm and 40 patients using routine 3.5-mm cortical screws, respectively. Time to fracture consolidation was 12.8 ± 7.8 months. No mal- or non-unions occurred during routine follow-up until 18 months postoperatively.

conclusionRestoring anatomic alignment in wedge or fragmentary clavicle fractures can ultimately be addressed using cortical screw augmentation. Both groups showed comparable results with respect to fracture reduction, fixation and stability as well as time to consolidation of the fracture, while the 2.0-mm screw diameter was associated with easier handling of small Fx fragments.

Indexed as

Bone ScrewsAdultBone PlatesClavicleFemaleFracture Fixation, InternalFractures, BoneHumansMaleMiddle AgedOpen Fracture ReductionRetrospective StudiesYoung AdultAlignmentClavicleCorticalFractureOsteosynthesisPlateScrew

Identifiers

PMID33531034
PMCPMC7851941

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.