Evidence map›Paper›PMID 33530789›Full record

ArticleThe Journal of international medical research2021

High-resolution vessel wall magnetic resonance imaging for depicting imaging features of unruptured intracranial vertebrobasilar dissecting aneurysms.

Binbin Sui, Xiaoyan Bai, Peiyi Gao, Yan Lin, Yisen Zhang, Jia Liang, Xinjian Yang

Open access · goldAbstract read
In one paragraph

Article in The Journal of international medical research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.5field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. The use of SNAP and T1-weighted VISTA in cervical artery dissection.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2023
    Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Binbin SuiTiantan Neuroimaging Center of Excellence, China National Clinical Research Center for Neurological Diseases, Beijing, China.ORCID https://orcid.org/0000-0002-1052-6992
Xiaoyan BaiDepartment of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing Neurosurgical Institute, Beijing, China.
Peiyi GaoDepartment of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing Neurosurgical Institute, Beijing, China.
Yan LinDepartment of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing Neurosurgical Institute, Beijing, China.
Yisen ZhangDepartment of Interventional Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Jia LiangDepartment of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing Neurosurgical Institute, Beijing, China.
Xinjian YangDepartment of Interventional Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Capital Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo demonstrate the application value of high-resolution vessel wall magnetic resonance imaging (HR-VW-MRI) for depicting the imaging features of unruptured intracranial vertebrobasilar dissecting aneurysms (VBDAs).

methodsHR-VW-MRI data of 49 patients with suspected unruptured VBDAs were retrospectively analyzed. The presence of intramural hematomas (IMH), double lumens, intimal flaps, and outer diameter enlargements were recorded. Specificity and sensitivity were calculated for both two-dimensional (2D) and three-dimensional (3D) sequences. Additionally, IMH volumes were measured and posterior inferior cerebellar artery (PICA) involvement was analyzed.

resultsThirty-five VBDAs were confirmed in 34 patients. The overall sensitivity and specificity were 0.889 (95% confidence interval [CI]: 0.730-0.964) and 0.769 (95% CI: 0.460-0.938) for 2D sequences, and 0.917 (95% CI: 0.764-0.978) and 0.846 (95% CI: 0.537-0.973) for 3D sequences, respectively. Intimal flaps were detected in 57.1%, 87.5%, and 71.4% of all cases on 2D pre-contrast T1-weighted, contrast-enhanced T1-weighted, and 3D T1-weighted black-blood (BB) images, respectively. There was no significant difference in IMH volume between 3D T1-weighted BB and magnetization-prepared rapid gradient-echo sequences. PICA involvement was best visualized using 3D T1 sequences.

conclusion3D T1-weighted BB MRI provided good visualization of VBDA features, with large coverage, and was useful for detecting dissection flaps.

Indexed as

Aortic DissectionIntracranial AneurysmHumansImaging, Three-DimensionalMagnetic Resonance AngiographyMagnetic Resonance ImagingRetrospective Studiesbasilar arteryhigh resolutionmagnetic resonance imagingT1-weighted black-blood MRIunruptured intracranial vertebrobasilar dissecting aneurysmsVertebral artery dissectionvessel wall imaging

Identifiers

PMID33530789
PMCPMC7871068
OpenAlexW3127199832

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.