Evidence map›Paper›PMID 33529996›Full record

ArticleJournal of the mechanical behavior of biomedical materials2021

Evaluation of the role of peripheral artery plaque geometry and composition on stent performance.

Christopher Noble, Kent D Carlson, Erica Neumann, Sean Doherty, Dan Dragomir-Daescu, Amir Lerman, Ahmet Erdemir, Melissa Young

Open access · greenAbstract read
In one paragraph

Article in Journal of the mechanical behavior of biomedical materials, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 12 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Christopher NobleDepartment of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.
Kent D CarlsonDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
Erica NeumannDepartment of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA.
Sean DohertyDepartment of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA.
Dan Dragomir-DaescuDepartment of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
Amir LermanDepartment of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.
Ahmet ErdemirDepartment of Biomedical Engineering and Computational Biomodeling (CoBi) Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA.
Melissa YoungDepartment of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA. Electronic address: young.melissa@mayo.edu.
Cleveland Clinic Lerner College of Medicine · USMayo Clinic in Arizona · USMayo Clinic in Florida · US

Funding

Mayo Clinic Center for Clinical and Translational Science (CCaTS UL1 Supplement - Dr. Timothy Curry)UL1TR002377 · NCATS · MAYO CLINIC ROCHESTER · PI VESNA D GAROVIC · 2017 to 2026
$78.4M
Automated patient specific artery modeling using ultrasound virtual histologyR01EB018965 · NIBIB · MAYO CLINIC ROCHESTER · PI YOUNG, MELISSA DENTON · 2016 to 2019
$1.7M
NCATS NIH HHS UL1 TR002377NIBIB NIH HHS R01 EB018965
6 · The paper itself

Abstract

Peripheral stent fracture is a major precursor to restenosis of femoral artery atherosclerosis that has been treated with stent implantation. In this work, we validate a workflow for performing in silico stenting on a patient specific peripheral artery with heterogeneous plaque structure. Six human cadaveric femoral arteries were imaged ex vivo using intravascular ultrasound virtual histology (IVUS-VH) to obtain baseline vessel geometry and plaque structure. The vessels were then stented and the imaging repeated to obtain the stented vessel lumen area. Finite element (FE) models were then constructed using the IVUS-VH images, where the material property constants for each finite element were calculated using the proportions of each plaque component in the element, as identified by the IVUS-VH images. A virtual stent was deployed in each FE model, and the model lumen area was calculated and compared to the experimental lumen area to validate the modeling approach. The model was then used to compare stent performance for heterogeneous and homogeneous artery models, to determine whether plaque geometry or composition had added effects on stent performance. We found that the simulated lumen areas were similar to the corresponding experimental values, despite using generic material constants. Additionally, the heterogeneous and homogeneous lumen areas were also similar, implying that plaque geometry is a stronger predictor of stent expansion performance than plaque composition. Comparing stent stress and strain for heterogeneous and homogeneous models, it was found that stress from these two models had a strong linear correlation, while the strain correlation was weaker but still present. This implies that stent performance may be predicted with a simple homogeneous material models accounting for overall geometry of the plaque, providing that stent fatigue is calculated using stress criteria.

Indexed as

Coronary Artery DiseasePlaque, AtheroscleroticCoronary VesselsFemoral ArteryHumansStentsUltrasonography, InterventionalFatigueFinite element methodIntravascular ultrasound virtual histologyNitinolPeripheral artery diseaseStenting

Identifiers

PMID33529996
PMCPMC7933123
OpenAlexW3123922343

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.