ArticleJournal of veterinary internal medicine2021
Assessment of postprandial hyperglycemia and circadian fluctuation of glucose concentrations in diabetic dogs using a flash glucose monitoring system.
Article in Journal of veterinary internal medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 21 citations in OpenAlex.
- Evaluation of low and high interstitial glucose concentrations in healthy, nondiabetic dogs using a flash glucose monitoring system.Journal of veterinary internal medicine · 2026Article
- Effect of a homemade diet compared to a commercial diet on glycaemic variability and glycaemic control assessed by continuous glucose monitoring system in diabetic dogs: a randomised crossover study.The Journal of small animal practice · 2026Article
- Aerobic exercise decreases interstitial glucose concentrations up to 2 h after exercise in dogs with insulin-treated diabetes mellitus: a preliminary study.Frontiers in veterinary science · 2025Article
- Comparison between a Flash Glucose Monitoring System and a Portable Blood Glucose Meter for Monitoring of Cats with Diabetic Ketosis or Ketoacidosis.Animals : an open access journal from MDPI · 2024Article
- Replacement of Dietary Carbohydrate with Protein versus Fat Differentially Alters Postprandial Circulating Hormones and Macronutrient Metabolism in Dogs.Metabolites · 2024Article
- Monitoring of Diabetes Mellitus Using the Flash Glucose Monitoring System: The Owners' Point of View.Veterinary sciences · 2023Article
- Effect of inhaled albuterol on whole blood potassium concentrations in dogs.Journal of veterinary internal medicine · 2022Article
- Evaluation of the FreeStyle Libre, a flash glucose monitoring system, in client-owned cats with diabetes mellitus.Journal of feline medicine and surgery · 2022Article
- Clinical Use of a 180-Day Implantable Glucose Monitoring System in Dogs with Diabetes Mellitus: A Case Series.Animals : an open access journal from MDPI · 2022Article
- Validation of a flash glucose monitoring system in outpatient diabetic cats.Journal of veterinary internal medicine · 2021Article
- Assessment of postprandial hyperglycemia and circadian fluctuation of glucose concentrations in diabetic dogs using a flash glucose monitoring system.Journal of veterinary internal medicine · 2021Article
- Article
- Freestyle Libre-Derived Metrics in Assessing Glycemic Control in Diabetic Dogs.Journal of veterinary internal medicineArticle
- A dose titration protocol for once-daily insulin glargine 300 U/mL for the treatment of diabetes mellitus in dogs.Journal of veterinary internal medicineArticle
- Effect of sodium-glucose cotransporter 2 inhibitor canagliflozin on interstitial glucose concentration in insulin-treated diabetic dogs.Journal of veterinary internal medicineArticle
- Assessment of the FreeStyle Libre 2 interstitial glucose monitor in hypo- and euglycemic cats.Journal of veterinary internal medicineArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
Abstract
backgroundPostprandial hyperglycemia (PPH) and circadian glucose concentration fluctuations recorded in the home environment of dogs with naturally occurring diabetes mellitus (DM) have not been reported.
objectivesTo determine if a flash glucose monitoring system (FGMS; FreeStyle Libre) can detect PPH and circadian fluctuations in glucose concentrations in dogs with variably controlled DM. ANIMALS: Fourteen client-owned dogs with DM.
methodsProspective observational study. Interstitial glucose (IG) concentrations measured by the FGMS during a 13-day study period were analyzed.
resultsA total of 17, 446 FGMS IG concentrations were analyzed. For all dogs analyzed together, median IG concentration measured within 30 (288 mg/dL), 60 (286 mg/dL), 90 (285 mg/dL), and 120 (285 mg/dL) minutes of meals was each significantly higher than the median IG concentration at all other times (260 mg/dL, 259 mg/dL, 258 mg/dL, and 257 mg/dL, respectively; range, 40-500 mg/dL; P < .001 for each). Median night-time IG concentration measured from all dogs on 3,547 samples recorded between 1:00 am and 6:00 am (268 mg/dL; range, 40-500 mg/dL) was significantly higher than median IG measured on 13, 899 samples at all other time points (259 mg/dL; range, 40-500 mg/dL; P < .001). CONCLUSIONS AND CLINICAL IMPORTANCE: The FGMS can be used for future studies of PPH and circadian fluctuations of glucose concentrations in dogs with DM in their home environment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.