Evidence map›Paper›PMID 33520383›Full record

ArticleBiomedical optics express2021

Correction of circumferential and longitudinal motion distortion in high-speed catheter/endoscope-based optical coherence tomography.

Tan Huu Nguyen, Osman Oguz Ahsen, Kaicheng Liang, Jason Zhang, Hiroshi Mashimo, James G Fujimoto

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.8field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 15 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. EndoscopicBiomedical optics express · 2022
    Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Tan Huu NguyenDepartment of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Osman Oguz AhsenDepartment of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Kaicheng LiangDepartment of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.ORCID https://orcid.org/0000-0003-3237-4034
Jason ZhangDepartment of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Hiroshi MashimoVeterans Affairs Boston Healthcare System, MA 02130, USA.
James G FujimotoDepartment of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
Massachusetts Institute of Technology · USPathAI (United States) · USVA Boston Healthcare System · US

Funding

Ultrahigh speed and resolution OCT/OCM using broadband swept VCSEL technologyR44CA101067 · NCI · PRAEVIUM RESEARCH, INC. · PI JAYARAMAN, VIJAYSEKHAR · 2003 to 2012
$2.9M
Low cost and high performance MEMS-VCSEL technology for next generation swept source optical coherence tomography and microscopyR44CA235904 · NCI · PRAEVIUM RESEARCH, INC. · PI JAYARAMAN, VIJAYSEKHAR · 2018 to 2020
$1.7M
Omniview tethered capsule for low cost, non-endoscopic Barrett's esophagus screening in unsedated patientsR01CA252216 · NCI · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI FUJIMOTO, JAMES G · 2020 to 2022
$1.0M
NCI NIH HHS R01 CA252216NCI NIH HHS R44 CA101067NCI NIH HHS R44 CA235904
6 · The paper itself

Abstract

Catheter/endoscope-based optical coherence tomography (OCT) is a powerful modality that visualizes structural information in luminal organs. Increases in OCT speed have reduced motion artifacts by enabling acquisition faster than or comparable to the time scales of physiological motion. However motion distortion remains a challenge because catheter/endoscope OCT imaging involves both circumferential and longitudinal scanning of tissue. This paper presents a novel image processing method to estimate and correct motion distortion in both the circumferential and longitudinal directions using a single en face image from a volumetric data set. The circumferential motion distortion is estimated and corrected using the en face image. Then longitudinal motion distortion is estimated and corrected using diversity of image features along the catheter pullback direction. Finally, the OCT volume is resampled and motion corrected. Results are presented on synthetic images and clinical OCT images of the human esophagus.

Identifiers

PMID33520383
PMCPMC7818954
OpenAlexW3110085794

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.