Evidence map›Paper›PMID 33513676›Full record

ArticleDiagnostics (Basel, Switzerland)2021

Bolus Intravenous Procainamide in Patients with Frequent Ventricular Ectopics during Cardiac Magnetic Resonance Scanning: A Way to Ensure High Quality Imaging.

Chrysovalantou Nikolaidou, Konstantinos Kouskouras, Nikolaos Fragakis, Vassilios P Vassilikos, Haralambos Karvounis, Theodoros D Karamitsos

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Chrysovalantou NikolaidouOxford Centre for Clinical Magnetic Resonance Research, University of Oxford, Oxford OX3 9DU, UK.
Konstantinos KouskourasDepartment of Radiology, AHEPA Hospital, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 546 36 Thessaloniki, Greece.
Nikolaos FragakisThird Department of Cardiology, Hippokration Hospital, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 546 43 Thessaloniki, Greece.
Vassilios P VassilikosThird Department of Cardiology, Hippokration Hospital, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 546 43 Thessaloniki, Greece.
Haralambos KarvounisFirst Department of Cardiology, AHEPA Hospital, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 546 36 Thessaloniki, Greece.
Theodoros D KaramitsosFirst Department of Cardiology, AHEPA Hospital, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 546 36 Thessaloniki, Greece.ORCID 0000-0002-4658-5273
Aristotle University of Thessaloniki · GR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Acquiring high-quality cardiac magnetic resonance (CMR) images in patients with frequent ventricular arrhythmias remains a challenge. We examined the safety and efficacy of procainamide when administered on the scanner table prior to CMR scanning to suppress ventricular ectopy and acquire high-quality images. Fifty consecutive patients (age 53.0 [42.0-58.0]; 52% female, left ventricular ejection fraction 55 ± 9%) were scanned in a 1.5 T scanner using a standard cardiac protocol. Procainamide was administered at intermittent intravenous bolus doses of 50 mg every minute until suppression of the ectopics or a maximum dose of 10 mg/kg. The average dose of procainamide was 567 ± 197 mg. Procainamide successfully suppressed premature ventricular contractions (PVCs) in 82% of patients, resulting in high-quality images. The baseline blood pressure (BP) was mildly reduced (mean change systolic BP -12 ± 9 mmHg; diastolic BP -4 ± 9 mmHg), while the baseline heart rate (HR) remained relatively unchanged (mean HR change -1 ± 6 bpm). None of the patients developed proarrhythmic changes. Bolus intravenous administration of procainamide prior to CMR scanning is a safe and effective alternative approach for suppressing PVCs and acquiring high-quality images in patients with frequent PVCs and normal or only mildly reduced systolic function.

Indexed as

cardiac magnetic resonanceCMR image qualitypremature ventricular contractionsprocainamideventricular arrhythmia

Identifiers

PMID33513676
PMCPMC7911068
OpenAlexW3126068203

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.