Evidence map›Paper›PMID 33513103›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2021

Simultaneous Noise Suppression and Incoherent Artifact Reduction in Ultrafast Ultrasound Vascular Imaging.

Chengwu Huang, Pengfei Song, Joshua D Trzasko, Ping Gong, U-Wai Lok, Shanshan Tang, Armando Manduca, Shigao Chen

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Article
  2. Article
  3. [Ultrasound technology's new application in the diagnosis and treatment of liver cancer].Zhonghua gan zang bing za zhi = Zhonghua ganzangbing zazhi = Chinese journal of hepatology · 2026
    Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. High-Resolution Power Doppler Using Null Subtraction Imaging.IEEE transactions on medical imaging · 2024
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Chengwu Huang
Pengfei Song
Joshua D Trzasko
Ping Gong
U-Wai Lok
Shanshan Tang
Armando Manduca
Shigao Chen

Funding

Quantitative Ultrasound Imaging Biomarkers of Crohn's DiseaseR01DK120559 · NIDDK · MAYO CLINIC ROCHESTER · PI BRUINING, DAVID HENRY, CHEN, SHIGAO · 2019 to 2022
$1.7M
Early prediction of colorectal liver metastases treatment response with ultrasound microvessel imagingR00CA214523 · NCI · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI SONG, PENGFEI · 2019 to 2021
$684k
NCI NIH HHS R00 CA214523NIDDK NIH HHS R01 DK120559
6 · The paper itself

Abstract

Ultrasound vascular imaging based on ultrafast plane wave imaging and singular value decomposition (SVD) clutter filtering has demonstrated superior sensitivity in blood flow detection. However, ultrafast ultrasound vascular imaging is susceptible to electronic noise due to the weak penetration of unfocused waves, leading to a lower signal-to-noise ratio (SNR) at larger depths. In addition, incoherent clutter artifacts originating from strong and moving tissue scatterers that cannot be completely removed create a strong mask on top of the blood signal that obscures the vessels. Herein, a method that can simultaneously suppress the background noise and incoherent artifacts is proposed. The method divides the tilted plane or diverging waves into two subgroups. Coherent spatial compounding is performed within each subgroup, resulting in two compounded data sets. An SVD-based clutter filter is applied to each data set, followed by a correlation between the two data sets to produce a vascular image. Uncorrelated noise and incoherent artifacts can be effectively suppressed with the correlation process, while the coherent blood signal can be preserved. The method was evaluated in wire-target simulations and phantom, in which around 7-10-dB SNR improvement was shown. Consistent results were found in a flow channel phantom with improved SNR by the proposed method (39.9 ± 0.2 dB) against conventional power Doppler (29.1 ± 0.6 dB). Last, we demonstrated the effectiveness of the method combined with block-wise SVD clutter filtering in a human liver, breast tumor, and inflammatory bowel disease data sets. The improved blood flow visualization may facilitate more reliable small vessel imaging for a wide range of clinical applications, such as cancer and inflammatory diseases.

Indexed as

ArtifactsUltrasonography, DopplerHumansImage Processing, Computer-AssistedPhantoms, ImagingSignal-To-Noise RatioUltrasonography

Identifiers

PMID33513103
PMCPMC8154644

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.