Evidence map›Paper›PMID 33511600›Full record

ArticleEuropean journal of dentistry2021

Effects of Long Durations of RF-Magnetron Sputtering Deposition of Hydroxyapatite on Titanium Dental Implants.

Ihab Nabeel Safi, Basima Mohammed Ali Hussein, Hikmat J Aljudy, Mustafa S Tukmachi

Abstract read
In one paragraph

Article in European journal of dentistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Surface Coatings of Dental Implants: A Review.Journal of functional biomaterials · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ihab Nabeel SafiDepartment of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq.
Basima Mohammed Ali HusseinDepartment of Biomedical Applications, Institute of Laser for Postgraduate Studies, University of Baghdad, Baghdad, Iraq.ORCID 0000-0001-7614-0710
Hikmat J AljudyDepartment of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq.
Mustafa S TukmachiDepartment of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesDental implant is a revolution in dentistry; some shortages are still a focus of research. This study use long duration of radiofrequency (RF)-magnetron sputtering to coat titanium (Ti) implant with hydroxyapatite (HA) to obtain a uniform, strongly adhered in a few micrometers in thickness. MATERIALS AND

methodsTwo types of substrates, discs and root form cylinders were prepared using a grade 1 commercially pure (CP) Ti rod. A RF-magnetron sputtering device was used to coat specimens with HA. Magnetron sputtering was set at 150 W for 22 hours at 100°C under continuous argon gas flow and substrate rotation at 10 rpm. Coat properties were evaluated via field emission scanning electron microscopy (FESEM), scanning electron microscopy-energy dispersive X-ray (EDX) analysis, atomic force microscopy, and Vickers hardness (VH). Student's

resultsAll FESEM images showed a homogeneous, continuous, and crack-free HA coat with a rough surface. EDX analysis revealed inclusion of HA particles within the substrate surface in a calcium (Ca)/phosphorus (P) ratio (16.58/11.31) close to that of HA. Elemental and EDX analyses showed Ca, Ti, P, and oxygen within Ti. The FESEM views at a cross-section of the substrate showed an average of 7 µm coat thickness. Moreover, these images revealed a dense, compact, and uniform continuous adhesion between the coat layer and the substrate. Roughness result indicated highly significant difference between uncoated Ti and HA coat (p-value < 0.05). A significant improvement in the VH value was observed when coat hardness was compared with the Ti substrate hardness (p-value < 0.05).

conclusionProlonged magnetron sputtering successfully coat Ti dental implants with HA in micrometers thickness which is well adhered essentially in excellent osseointegration.

Identifiers

PMID33511600
PMCPMC8382459

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.