Trial reportJournal of gastroenterology and hepatology2021
Amount of contamination on the face shield of endoscopists during upper endoscopy between patients in two positions: A randomized study.
Trial report in Journal of gastroenterology and hepatology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04981535 (The Comparison of Level of Aerosol Particle at the Face Level of Endoscopist Performing Upper Gastrointestinal Endoscopy in Patients With and Without Head Box; a Randomized Control Trial), which is not on this map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Comparison of Level of Aerosol Particle at the Face Level of Endoscopist Performing Upper Gastrointestinal Endoscopy in Patients With and Without Head Box; a Randomized Control Trial
Who cites it
6 citing papers in PubMed, 8 citations in OpenAlex.
- Amount of contamination on the face shield of endoscopists during upper endoscopy between patients in two positions: A randomized study.Journal of gastroenterology and hepatology · 2021Trial
- The new 222-nm far ultraviolet-C lowers bacterial contamination to endoscopists during esophagogastroduodenoscopy.DEN open · 2024Article
- Article
- Does an Extraoral Suction Device Reduce Aerosol Generation and Prevent Droplet Exposure to the Examiner during Esophagogastroduodenoscopy?Journal of clinical medicine · 2023Article
- Bacterial contamination of endoscopist and assistant face visors during gastrointestinal endoscopy: a pilot study.Frontline gastroenterology · 2023Article
- Clinical Efficacy of Novel Patient-Covering Negative-Pressure Box for Shielding Virus Transmission during Esophagogastroduodenoscopy: A Prospective Observational Study.Diagnostics (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND AND
aimDuring the Coronavirus Disease 2019 pandemic, esophagogastroduodenoscopy (EGD) has been recognized as an aerosol-generating procedure. This study aimed to systematically compare the degree of face shield contamination between endoscopists who performed EGD on patients lying in the left lateral decubitus (LL) and prone positions.
methodsThis is a randomized trial in patients scheduled for EGD between April and June 2020. Eligible 212 patients were randomized with 1:1 allocation. Rapid adenosine triphosphate test was used to determine contamination level using relative light units of greater than 200 as a cutoff value. All eligible patients were randomized to lie in either the LL or prone position during EGD. The primary outcome was the rate of contamination on the endoscopist's face shield.
resultsThe majority of patients were female (63%), with a mean age of 60 ± 13 years. Baseline characteristics were comparable between the two groups. There was no face shield contamination after EGD in either group. The number of coughs in the LL group was higher than the prone group (1.38 ± 1.8 vs 0.89 ± 1.4, P = 0.03). The mean differences in relative light units on the face shield before and after EGD in the LL and prone groups were 9.9 ± 20.9 and 4.1 ± 6 (P = 0.008), respectively.
conclusionAs measured by the adenosine triphosphate test, performing diagnostic EGD does not lead to contamination on the face shield of the endoscopist. However, placing patients in the prone position may further mitigate the risk.