Comparison of Differences in Bone Mineral Density Measurement With 3 Hologic Dual-Energy X-Ray Absorptiometry Scan Modes.
Article in Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Comparative analysis of vision transformers and convolutional neural networks in osteoporosis detection from X-ray images.Scientific reports · 2024Article
- High systemic immune-inflammation index is relevant to osteoporosis among middle-aged and older people: A cross-sectional study.Immunity, inflammation and disease · 2023Article
- A cross-calibration study using a novel dual X-ray absorptiometry system for bone mineral density measurements with the European Spine Phantom.Quantitative imaging in medicine and surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Bone mineral density (BMD) measurement using dual-energy X-ray absorptiometry (DXA) is considered a diagnostic parameter for osteoporosis by the World Health Organization (WHO). DXA densitometers have different scanning modes for BMD measurements, although the specific scanning modes vary based upon the manufacturer. For DXA machines manufactured by Hologic, which are used globally, a range of scanning modes exist, including but not limited to (in order of decreasing spatial resolution) Array, Fast Array, and Express Array. Only a handful of prior studies have compared the reproducibility of BMD measurements across scan modes. The present study aimed to add to this body of literature by investigating the differences in BMD measured between 3 scanning modes in Hologic DXA machines at 19 different health centers. As part of cross-calibration activities for two multi-center studies in China measuring BMD, the European spine phantom (ESP, 1.000 g/cm