Evidence map›Paper›PMID 33501298›Full record

ArticleFrontiers in robotics and AI2020

Dielectric Elastomer Actuator Driven Soft Robotic Structures With Bioinspired Skeletal and Muscular Reinforcement.

M Franke, A Ehrenhofer, S Lahiri, E-F M Henke, T Wallmersperger, A Richter

Abstract read
In one paragraph

Article in Frontiers in robotics and AI, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Integrated Actuation and Sensing: Toward Intelligent Soft Robots.Cyborg and bionic systems (Washington, D.C.) · 2024
    Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

M FrankeInstitute of Semiconductors and Microsystems (IHM), Technische Universität Dresden, Dresden, Germany.
A EhrenhoferInstitute of Solid Mechanics, Technische Universität Dresden, Dresden, Germany.
S LahiriInstitute of Semiconductors and Microsystems (IHM), Technische Universität Dresden, Dresden, Germany.
E-F M HenkeInstitute of Semiconductors and Microsystems (IHM), Technische Universität Dresden, Dresden, Germany.
T WallmerspergerInstitute of Solid Mechanics, Technische Universität Dresden, Dresden, Germany.
A RichterInstitute of Semiconductors and Microsystems (IHM), Technische Universität Dresden, Dresden, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Natural motion types found in skeletal and muscular systems of vertebrate animals inspire researchers to transfer this ability into engineered motion, which is highly desired in robotic systems. Dielectric elastomer actuators (DEAs) have shown promising capabilities as artificial muscles for driving such structures, as they are soft, lightweight, and can generate large strokes. For maximum performance, dielectric elastomer membranes need to be sufficiently pre-stretched. This fact is challenging, because it is difficult to integrate pre-stretched membranes into entirely soft systems, since the stored strain energy can significantly deform soft elements. Here, we present a soft robotic structure, possessing a bioinspired skeleton integrated into a soft body element, driven by an antagonistic pair of DEA artificial muscles, that enable the robot bending. In its equilibrium state, the setup maintains optimum isotropic pre-stretch. The robot itself has a length of 60 mm and is based on a flexible silicone body, possessing embedded transverse 3D printed struts. These rigid bone-like elements lead to an anisotropic bending stiffness, which only allows bending in one plane while maintaining the DEA's necessary pre-stretch in the other planes. The bones, therefore, define the degrees of freedom and stabilize the system. The DEAs are manufactured by aerosol deposition of a carbon-silicone-composite ink onto a stretchable membrane that is heat cured. Afterwards, the actuators are bonded to the top and bottom of the silicone body. The robotic structure shows large and defined bimorph bending curvature and operates in static as well as dynamic motion. Our experiments describe the influence of membrane pre-stretch and varied stiffness of the silicone body on the static and dynamic bending displacement, resonance frequencies and blocking forces. We also present an analytical model based on the Classical Laminate Theory for the identification of the main influencing parameters. Due to the simple design and processing, our new concept of a bioinspired DEA based robotic structure, with skeletal and muscular reinforcement, offers a wide range of robotic application.

Indexed as

anisotropybimorph actuationdielectric elastomer actuatormodelling and simulationpre-stretchsiliconeskeletonsoft robot

Identifiers

PMID33501298
PMCPMC7805688

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked