ArticleFrontiers in robotics and AI2019
Deployable, Variable Stiffness, Cable Driven Robot for Minimally Invasive Surgery.
Article in Frontiers in robotics and AI, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 49 citations in OpenAlex.
- Perioperative outcomes of the SHURUI single-port robotic system in urologic surgery: a systematic review and single-arm meta-analysis.Journal of robotic surgery · 2025Pooled it
- Mechanically adaptive materials with tunable stiffness for biomedical devices: Mechanisms, applications, and perspectives.Materials today. Bio · 2026Review
- Development of structured fabric-based endoscopic guiding sheath with tunable diameter and stiffness functions.Journal of robotic surgery · 2025Article
- A Tension Sensor Array for Cable-Driven Surgical Robots.Sensors (Basel, Switzerland) · 2024Article
- Transcutaneous fluorescence spectroscopy: development and characterization of a compact, portable, and fiber-optic sensor.Journal of biomedical optics · 2024Article
- Tissue palpation in endoscopy using EIT and soft actuators.Frontiers in robotics and AI · 2024Article
- Design and evaluation of a pneumatic actuation unit for a wasp-inspired self-propelled needle.PloS one · 2024Article
- A Hybrid Controller for a Soft Pneumatic Manipulator Based on Model Predictive Control and Iterative Learning Control.Sensors (Basel, Switzerland) · 2023Article
- A Dexterous Robotic System for Autonomous Debridement of Osteolytic Bone Lesions in Confined Spaces: Human Cadaver Studies.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2022Article
- The Role of Soft Robotic Micromachines in the Future of Medical Devices and Personalized Medicine.Micromachines · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Minimally Invasive Surgery (MIS) imposes a trade-off between non-invasive access and surgical capability. Treatment of early gastric cancers over 20 mm in diameter can be achieved by performing Endoscopic Submucosal Dissection (ESD) with a flexible endoscope; however, this procedure is technically challenging, suffers from extended operation times and requires extensive training. To facilitate the ESD procedure, we have created a deployable cable driven robot that increases the surgical capabilities of the flexible endoscope while attempting to minimize the impact on the access that they offer. Using a low-profile inflatable support structure in the shape of a hollow hexagonal prism, our robot can fold around the flexible endoscope and, when the target site has been reached, achieve a 73.16% increase in volume and increase its radial stiffness. A sheath around the variable stiffness structure delivers a series of force transmission cables that connect to two independent tubular end-effectors through which standard flexible endoscopic instruments can pass and be anchored. Using a simple control scheme based on the length of each cable, the pose of the two instruments can be controlled by haptic controllers in each hand of the user. The forces exerted by a single instrument were measured, and a maximum magnitude of 8.29 N observed along a single axis. The working channels and tip control of the flexible endoscope remain in use in conjunction with our robot and were used during a procedure imitating the demands of ESD was successfully carried out by a novice user. Not only does this robot facilitate difficult surgical techniques, but it can be easily customized and rapidly produced at low cost due to a programmatic design approach.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.