Evidence map›Paper›PMID 33498610›Full record

ArticleJournal of clinical medicine2021

The Loop Tenodesis Procedure-From Biomechanics to First Clinical Results.

Moritz Riedl, Agnes Mayr, Stefan Greiner, Christian Pfeifer, Isabella Weiss, Lina Forchhammer, Volker Alt, Maximilian Kerschbaum

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Moritz RiedlClinic of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany.ORCID 0000-0003-3414-6596
Agnes MayrClinic of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany.
Stefan GreinerSporthopaedicum Straubing, Bahnhofplatz 27, 94315 Straubing, Germany.
Christian PfeiferClinic of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany.ORCID 0000-0002-1403-0476
Isabella WeissClinic of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany.
Lina ForchhammerClinic of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany.
Volker AltClinic of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany.
Maximilian KerschbaumClinic of Trauma Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany.
University Hospital Regensburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Introduction: Several surgical therapy options for the treatment of pathologies of the long biceps tendon (LHB) have been established. However, tenotomy, as well as established tenodesis techniques, has disadvantages, such as cosmetic deformities, functional impairments and residual shoulder pain. This study presents the first clinical and structural results of the recently introduced loop tenodesis procedure for the LHB, developed to overcome these issues. (2) Methods: 37 patients (11 women, 26 men, mean age 52 years), who underwent loop tenodesis of the LHB were examined six months after surgery. For the clinical evaluation the Constant score, as well as the LHB score, were used, complemented by elbow flexion and supination strength measurements. The integrity of the tenodesis construct was evaluated indirectly by sonographic detection of the LHB in the bicipital groove. (3) Results: Both, the overall Constant score as well as the LHB score showed significant improvements six months postoperatively, as compared to the preoperative value. Fourteen patients (38%) presented an examiner-dependent upper arm deformity, although only five patients (13%) reported subjective cosmetic deformities. Both, flexion and supination strength were preserved compared to the preoperative level. In 35 patients (95%), the tenodesis in the bicipital groove was proofed sonographically. (4) Conclusion: The loop tenodesis of the LHB provides good-to-excellent overall clinical results after a short-term follow-up of six month. The incidence of cosmetic deformities was inferior compared to conventional therapy options (tenotomy and anchor tenodesis).

Indexed as

arthroscopyLHBlong biceps tendonshouldertenodesistenotomy

Identifiers

PMID33498610
PMCPMC7865652
OpenAlexW3121510460

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked