ArticleMicromachines2021
Innovative 3D Microfluidic Tools for On-Chip Fluids and Particles Manipulation: From Design to Experimental Validation.
Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- A Review on Micromixers, Microdroplet Generators and Their Integration.Micromachines · 2026Review
- Single-Imaging Parasite-Quantification Microfluidic Device for Detection and Analysis of Schistosoma Eggs in Urine.Micromachines · 2026Article
- Transformation gap from research findings to large-scale commercialized products in microfluidic field.Materials today. Bio · 2024Review
- A Microfluidic-Based Sensing Platform for Rapid Quality Control on Target Cells from Bioreactors.Sensors (Basel, Switzerland) · 2024Article
- Recent Developments in Inertial and Centrifugal Microfluidic Systems along with the Involved Forces for Cancer Cell Separation: A Review.Sensors (Basel, Switzerland) · 2023Review
- A Novel Hybrid Platform for Live/Dead Bacteria Accurate Sorting by On-Chip DEP Device.International journal of molecular sciences · 2023Article
- Miniaturized Real-Time PCR systems for SARS-CoV-2 detection at the Point-of-Care.Clinica chimica acta; international journal of clinical chemistry · 2022Review
- Bonding Strategies for Thermoplastics Applicable for Bioanalysis and Diagnostics.Micromachines · 2022Review
- Femtosecond Laser Fabrication of Microporous Membranes for Biological Applications.Micromachines · 2022Article
- Recent Advances in Thermoplastic Microfluidic Bonding.Micromachines · 2022Review
- Editorial for the Special Issue on Particles Separation in Microfluidic Devices, Volume II.Micromachines · 2022Article
- Microfluidic Point-of-Care (POC) Devices in Early Diagnosis: A Review of Opportunities and Challenges.Sensors (Basel, Switzerland) · 2022Review
- Beyond liquid biopsy: Toward non-invasive assays for distanced cancer diagnostics in pandemics.Biosensors & bioelectronics · 2022Review
- SMILE Platform: An Innovative Microfluidic Approach for On-Chip Sample Manipulation and Analysis in Oral Cancer Diagnosis.Micromachines · 2021Article
- Fabrication Methods for Microfluidic Devices: An Overview.Micromachines · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Micromixers are essential components in lab-on-a-chip devices, of which the low efficiency can limit many bio-application studies. Effective mixing with automation capabilities is still a crucial requirement. In this paper, we present a method to fabricate a three-dimensional (3D) poly(methyl methacrylate) (PMMA) fluidic mixer by combining computer-aided design (CAD), micromilling technology, and experimental application via manipulating fluids and nanoparticles. The entire platform consists of three microfabricated layers with a bottom reservoir-shaped microchannel, a central serpentine channel, and a through-hole for interconnection and an upper layer containing inlets and outlet. The sealing process of the three layers and the high-precision and customizable methods used for fabrication ensure the realization of the monolithic 3D architecture. This provides buried running channels able to perform passive chaotic mixing and dilution functions, thanks to a portion of the pathway in common between the reservoir and serpentine layers. The possibility to plug-and-play micropumping systems allows us to easily demonstrate the feasibility and working features of our device for tracking the mixing and dilution performances of the micromixer by using colored fluids and fluorescent nanoparticles as the proof of concept. Exploiting the good transparency of the PMMA, spatial liquid composition and better control over reaction variables are possible, and the real-time monitoring of experiments under a fluorescence microscope is also allowed. The tools shown in this paper are easily integrable in more complex lab-on-chip platforms.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.