ArticleThe Analyst2021
Flow control in a laminate capillary-driven microfluidic device.
Article in The Analyst, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed.
- Self-Powered Microfluidic Device with Laser-Converted Graphene Electrodes for Immobilization-Free Electrochemical Detection of MPOX Virus DNA via Mismatch-Driven Nanocomplexes.Small (Weinheim an der Bergstrasse, Germany) · 2026Article
- Modeling and validation of parallel co-flows layer widths in open-capillary trigger valve systems.bioRxiv : the preprint server for biology · 2026Article
- Sponge-Based Flow Control in Laminate Capillary-Driven Electrochemical Microfluidic Devices for Viscous Sample Analysis.Analytical chemistry · 2026Article
- Capillary microfluidics aided single-cell manipulation for optical detection of bacterial pathogens.Biophysical reviews · 2026Review
- Modular Scaffold Crystals for Programmable Installation and Structural Observation of DNA-Binding Proteins.bioRxiv : the preprint server for biology · 2026Article
- Article
- Microfluidic technologies for wearable and implantable biomedical devices.Lab on a chip · 2025Review
- Paper as a Sustainable Material for Smart Electrochemical (Bio)sensors with Unprecedented Features: A Perspective.Analytical chemistry · 2025Review
- NFC Smartphone-Based Electrochemical Microfluidic Device Integrated with Nanobody Recognition for C-Reactive Protein.ACS sensors · 2024Article
- Advancements in the research of finger-actuated POCT chips.Mikrochimica acta · 2023Review
- Recent Advances in Skin-Interfaced Wearable Sweat Sensors: Opportunities for Equitable Personalized Medicine and Global Health Diagnostics.ACS sensors · 2023Review
- Capillary flow-driven immunoassay platform for COVID-19 antigen diagnostics.Analytica chimica acta · 2023Article
- Microfluidic pumps for cell sorting.Biomicrofluidics · 2023Review
- Capillary driven microfluidic sequential flow device for point-of-need ELISA: COVID-19 serology testing.Analytical methods : advancing methods and applications · 2023Article
- Electric field and viscous fluid polarity effects on capillary-driven flow dynamics between parallel plates.Heliyon · 2023Article
- Electrochemical Capillary Driven Immunoassay for Detection of SARS-CoV-2.ACS measurement science au · 2022Article
- A Review of Microfluidic Experimental Designs for Nanoparticle Synthesis.International journal of molecular sciences · 2022Review
- Simple manipulation of enzyme-linked immunosorbent assay (ELISA) using an automated microfluidic interface.Analytical methods : advancing methods and applications · 2022Article
- Hand-Powered Inertial Microfluidic Syringe-Tip Centrifuge.Biosensors · 2021Article
- Electrochemical Capillary-Flow Immunoassay for Detecting Anti-SARS-CoV-2 Nucleocapsid Protein Antibodies at the Point of Care.ACS sensors · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Capillary-driven microfluidic devices are of significant interest for on-site analysis because they do not require external pumps and can be made from inexpensive materials. Among capillary-driven devices, those made from paper and polyester film are among the most common and have been used in a wide array of applications. However, since capillary forces are the only driving force, flow is difficult to control, and passive flow control methods such as changing the geometry must be used to accomplish various analytical applications. This study presents several new flow control methods that can be utilized in a laminate capillary-driven microfluidic device to increase available functionality. First, we introduce push and burst valve systems that can stop and start flow. These valves can stop flow for >30 min and be opened by either pressing the channel or inflowing other fluids to the valve region. Next, we propose flow control methods for Y-shaped channels that enable more functions. In one example, we demonstrate the ability to accurately control concentration to create laminar, gradient, and fully mixed flows. In a second example, flow velocity in the main channel is controlled by adjusting the length of the inlet channel. In addition, the flow velocity is constant as the inlet length increases. Finally, the flow velocity in the Y-shaped device as a function of channel height and fluid properties such as viscosity and surface tension was examined. As in previous studies on capillary-driven channels, the flow rate was affected by each parameter. The fluidic control tools presented here will enable new designs and functions for low cost point of need assays across a variety of fields.