Evidence map›Paper›PMID 33490605›Full record

ArticleTrauma surgery & acute care open2021

Size matters: first-in-human study of a novel 4 French REBOA device.

Adam Power, Asha Parekh, Oonagh Scallan, Shane Smith, Teresa Novick, Neil Parry, Laura Moore

Open access · goldAbstract read
In one paragraph

Article in Trauma surgery & acute care open, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 39 citations in OpenAlex.

  1. Article
  2. Resuscitative endovascular balloon occlusion of the aorta in trauma patients: Past, present, and future.Chinese journal of traumatology = Zhonghua chuang shang za zhi · 2026
    Review
  3. Article
  4. Article
  5. A novel technique for proximal inferior vena cava control during tumor thrombectomy using the COBRA-OS balloon.Canadian Urological Association journal = Journal de l'Association des urologues du Canada · 2024
    Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Adam PowerSurgery, Western University, London, Canada.
Asha ParekhSurgery, Western University, London, Canada.
Oonagh ScallanSurgery, Western University, London, Canada.
Shane SmithSurgery, Western University, London, Canada.
Teresa NovickSurgery, Western University, London, Canada.
Neil ParrySurgery, Western University, London, Canada.
Laura MooreSurgery, University of Texas McGovern Medical School, Houston, Texas, USA.
Western University · CAThe University of Texas Health Science Center at Houston · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundResuscitative endovascular balloon occlusion of the aorta (REBOA) is an emerging technique used for non-compressible torso hemorrhage. However, its current use continues to be limited and there is a need for a simple, fast, and low profile REBOA device. Our objective was to evaluate the feasibility of a novel 4 French REBOA device called the COBRA-OS (Control of Bleeding, Resuscitation, Arterial Occlusion System).

methodsThis study is the first-in-human feasibility trial of the COBRA-OS. Due to the difficulty of trialing the device in the trauma setting, we performed a feasibility study using organ donors (due to the potential usefulness of the COBRA-OS for normothermic regional perfusion) after neurological determination of death (NDD) prior to organ retrieval. Bilateral 4 French introducer sheaths were placed in both femoral arteries and the COBRA-OS was advanced up the right side and deployed in the thoracic aorta (Zone 1). Once aortic occlusion was confirmed via the left-sided arterial line, the device was deflated, moved to the infrarenal aorta (Zone 3), and redeployed.

resultsA total of 7 NDD organ donors were entered into the study, 71% men, with a mean age 46.6 years (range 26 to 64). The COBRA-OS was able to occlude the aorta in Zones 1 and 3 in all patients. The mean time of placing a 4 French sheath was 47.7 seconds (n=13, range 28 to 66 seconds). The mean time from skin to Zone 1 aortic occlusion was 70.1 seconds (range 58 to 105 seconds); mean balloon volumes were 15 mL for Zone 1 (range 13 to 20 mL) and 9 mL for Zone 3 (range 6 to 15 mL); there were no complications and visual inspection of the aorta in all patients revealed no injury. DISCUSSION: The COBRA-OS is a novel 4 French REBOA device that has demonstrated fast and safe aortic occlusion in this first-in-human feasibility study. LEVEL OF EVIDENCE: Level V, therapeutic.

Indexed as

COBRA-OSorgan donorREBOAtrauma

Identifiers

PMID33490605
PMCPMC7798668
OpenAlexW3121059253

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.