ArticleAnnals of translational medicine2020
The anatomic basis for ultrasound in the diagnosis and treatment of styloid process-related diseases.
Article in Annals of translational medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 8 citations in OpenAlex.
- Diagnostic accuracy of panoramic radiography in detecting styloid process elongation: a cone-beam computed tomography referenced retrospective study.BMC oral health · 2025Article
- The Anatomy of the Stylohyoid Chain: A Systematic Review with Meta-Analysis.Diagnostics (Basel, Switzerland) · 2025Review
- Vascular Eagle Syndrome in Elderly Patients Diagnosed by Dynamic Magnetic Resonance Angiography: A Case Report and Literature Review.NMC case report journal · 2025Article
- Elongated styloid syndrome mimicking temporomandibular joint disorders: a case report and short literature review.Journal of the Korean Association of Oral and Maxillofacial Surgeons · 2023Article
- Clinical efficacy of styloid incision truncation via percutaneous punching in treating styloid process syndrome.Journal of orthopaedic surgery and research · 2023Article
- The External Carotid Artery and the Styloid Process.Current health sciences journalArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe styloid process (SP), stylohyoid ligament and lesser horn of hyoid bone together form the stylohyoid chain. Differences in the ossification degree and the connection sites of each segment of the stylohyoid chain on both sides lead to variations in the length, orientation, thickness, and straightness of SP. The incidence of elongation of the SP, known as styloid process syndrome (SPS), is around 4%, with only 4% of patients showing elongation show symptoms. Computed tomography (CT) remains the first-choice auxiliary examination for diagnosing SPS, but its performance can be affected by a variety of factors. Ultrasound can reveal the parapharyngeal space and adjacent structures, which offer high consistency with CT findings. Here, we investigated the ultrasonographic features of the SP and its adjacent structures in normal adults and assessed the clinical utility of ultrasound assessment for SP-related diseases.
methodsWith the ramus of mandible, mastoid process, SP, and salivary gland as the anatomical landmarks, ultrasonography was conducted on the parapharyngeal space in 78 healthy adults. The scans were performed along the oblique coronal section of the ramus and the cross-sectional plane between the mastoid process and ramus to visualize the SP and its adjacent structures. The SP length, the shortest distance from the SP tip to the outer edge of tonsil (SP-tonsil distance), and the distance from SP to the internal carotid artery (SP-ICA distance) were measured.
resultsSP and its adjacent structures were successfully visualized on ultrasonography in all 78 subjects. The measured SP length was 2.65±0.48 cm. The SP-tonsil distance was 1.95±0.50 cm. The SP-ICA distance was 0.509±0.231 cm. The SP length and SP-tonsil distance measured by ultrasound were not significantly different from those measured by CT (P=0.071, P=0.053). Furthermore, the SP length and SP-tonsil distance measured by ultrasound were positively correlated with CT measurements (r=0.917, P=0.071; r=0.978, P=0.053, respectively). SP-tonsil distance was negatively correlated with SP length and SP inward deflection angle.
conclusionsUltrasound can accurately reveal the shape and size of SP and its adjacent structures and thus will be helpful for the diagnosis of SP-related diseases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.