Evidence map›Paper›PMID 33489788›Full record

ArticleBiotechnology reports (Amsterdam, Netherlands)2021

Cortisol AuPd plasmonic unclad POF biosensor.

Cátia Leitão, Arnaldo Leal-Junior, Ana R Almeida, Sónia O Pereira, Florinda M Costa, João L Pinto, C Marques

Open access · goldAbstract read
In one paragraph

Article in Biotechnology reports (Amsterdam, Netherlands), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
12.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 138 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Review
  9. Review
  10. Review
  11. Article
  12. Review
  13. Article
  14. Review
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Cátia Leitãoi3N, Department of Physics, University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal.
Arnaldo Leal-JuniorGraduate Program of Electrical Engineering & Mechanical Engineering Department, Federal University of Espirito Santo, Vitória, 29075-910, Brazil.
Ana R Almeidai3N, Department of Physics, University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal.
Sónia O Pereirai3N, Department of Physics, University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal.
Florinda M Costai3N, Department of Physics, University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal.
João L Pintoi3N, Department of Physics, University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal.
C Marquesi3N, Department of Physics, University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal.
University of Aveiro · PTUniversidade Federal do Espírito Santo · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents the development and feasibility tests of a cortisol immunosensor. The sensor is based on surface plasmon resonance (SPR) using an unclad plastic optical fiber (POF) in which the SPR is used as sensitivity enhancer, promoted by a gold/palladium (AuPd) alloy coating. The AuPd coated fibers were functionalized with an anti-cortisol antibody and passivated with bovine serum albumin (BSA) to be tested in the presence of cortisol as target analyte. The antibody-antigen binding reaction caused a variation of the refractive index on the surface of the AuPd coating, which leads to a shift of the SPR signature wavelength. The sensor was tested for different cortisol concentrations, ranging from 0.005 to 10 ng/mL. The reported biosensor presented a total wavelength shift of 15 nm for the testing range, putting in evidence a high sensitivity. Control tests for selectivity assessment were also performed. Concentrations as high as 10 ng/mL of cortisol, in a sensor functionalized with anti-hCG antibodies, only resulted in 1 nm variation of the resonance wavelength, 15 times lower than the one functionalized with the anti-cortisol antibodies, which indicates a high selectivity for the proposed approach. For this sensing approach the limit of detection (LOD) was determined to be 1 pg/mL. The proposed SPR based POF sensor has a low-cost interrogation method, high sensitivity and low LOD, straightforward signal processing and find important applications in different biological fields.

Indexed as

BiosensorPlastic optical fiberSPRStress monitoringUnclad POFWell-being monitoring

Identifiers

PMID33489788
PMCPMC7809164
OpenAlexW3119561004

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.