Evidence map›Paper›PMID 33488863›Full record

ArticleArchives of medical science : AMS2021

Use of O-arm with neuronavigation in percutaneous vertebroplasty reduces the surgeon's exposure to intraoperative radiation.

Maciej Wojdyn, Olaf Pierzak, Krzysztof Zapałowicz, Maciej Radek

Open access · goldAbstract read
In one paragraph

Article in Archives of medical science : AMS, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Maciej WojdynDepartment of Neurosurgery, Surgery of Spine and Peripheral Nerves, Medical University of Lodz, University Hospital WAM-CSW, Lodz, Poland.
Olaf PierzakDepartment of Neurosurgery, Surgery of Spine and Peripheral Nerves, Medical University of Lodz, University Hospital WAM-CSW, Lodz, Poland.
Krzysztof ZapałowiczDepartment of Neurosurgery, Prof. Gibiński Central Clinical Hospital, Katowice, Poland.
Maciej RadekDepartment of Neurosurgery, Surgery of Spine and Peripheral Nerves, Medical University of Lodz, University Hospital WAM-CSW, Lodz, Poland.
Medical University of Lodz · PLCentral Clinical Hospital · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPercutaneous vertebroplasty is commonly used to treat spinal fractures. The authors compare radiation exposure as potential risk for the surgical team during vertebroplasty guided by O-arm combined with neuronavigation versus vertebroplasty guided by C-arm fluoroscopy. MATERIAL AND

methodsThe clinical material consisted of a group of 29 patients (44 vertebrae) with fractures of the thoracolumbar spine treated with percutaneous vertebroplasty guided by O-arm with neuronavigation. In this new method, the operating room staff leaves the operating room for the duration of the 3D scan of the appropriate spine section using the O-arm. In the next stage, the needle of the vertebroplasty system is introduced using only neuronavigation without the need for a radiological view. Finally, the cement injection was made under O-arm fluoroscopic control. The comparison group consisted of a group of 35 patients (40 vertebrae) treated with the classical method using C-arm fluoroscopy. The two methods were compared in terms of the average dose of emitted ionizing radiation through the device (O-arm vs. C-arm) to which surgeons are exposed during percutaneous vertebroplasty.

resultsAs a result of vertebroplasty procedures guided by neuronavigation, a statistically significant difference between the values of mean dose of radiation emitted by O-arm and C-arm systems was noted. The O-arm emitted 912 cGy/cm

conclusionsDuring vertebroplasty with the O-arm combined with neuronavigation the radiation dose is significantly lower as compared with the C-arm used for fluoroscopic guidance, minimizing the potential risk of radiation exposure to surgeons.

Indexed as

fluoroscopyneuronavigationO-armradiation exposurevertebral fracturevertebroplasty

Identifiers

PMID33488863
PMCPMC7811320
OpenAlexW2939218195

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.