Evidence map›Paper›PMID 33487860›Full record

ArticleMedical journal, Armed Forces India2021

Use of immunoadsorption columns in ABO-incompatible renal transplantation: A prospective study at a tertiary care center in India.

D Mukherjee, A K Hooda, A Jairam, Ranjith K Nair, Sourabh Sharma

Open access · greenAbstract read
In one paragraph

Article in Medical journal, Armed Forces India, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact, top 77% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

D MukherjeeSenior Advisor (Med & Nephrology), Army Hospital (R&R), Delhi Cantt, India.
A K HoodaDirector General (Org & Pers), O/o DGAFMS, Ministry of Defence, 'M' Block, New Delhi 110001, India.
A JairamConsultant (Med & Nephrology), Command Hospital (Eastern Command), Kolkata, India.
Ranjith K NairSenior Advisor (Med & Nephrology), Command Hospital (Eastern Command), Kolkata, India.
Sourabh SharmaSenior Resident (Med & Nephrology), Army Hospital (R&R), Delhi Cantt, India.
Army Hospital Research and Referral · INCommand Hospital · INMinistry of Defence · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWe present our experience of ABO-incompatible renal transplant using immunoadsorption (IA) columns. We have compared efficacy of two commercially available columns.

methodsThis single-center prospective study was conducted at Army Hospital Research and Referral, Delhi. All consecutive ABO-incompatible renal transplants from January 2014 to February 2018 were analyzed. Of 30 patients who underwent transplantations, 28 underwent antibody depletion with immunoadsorption columns. Of them, 14 cases were in the "Glycosorb group," while 14 in the "Adsopak group."

resultsThe donors in the Adsopak group were older than those in the Glycosorb group (p < 0.05). Both groups had spousal donors in majority. The cutoff for the antibody titer was 1:8. The median titer in the Adsopak group was 128 (range, 1:4 to 1:2048), while that in the Glycosorb group was 24 (range, 1:8 to 1:128). All patients in the Glycosorb group had baseline titers ≤1:128, while 13 patients in the Adsopak group had baseline titers ≤1:512. Nil titer was achievable with Glycosorb® (50%,7/14) but not with Adsopak® (P < 0.01). Around 4 sessions were required for the Glycosorb group, while around 8 sessions were required for the Adsopak group before transplantation (p < 0.001). The Glycosorb group was advantageous in terms of graft failure because no rejection was noticed in these patients in their follow-up period. Three patients in the Adsopak group developed rejection (two had mixed rejection, and one had antibody-mediated rejection). Four patients died of sepsis (three in the Glycosorb and one in the Adsopak group). Lower baseline serum creatinine level was achieved in the Glycosorb group.

conclusionsResults of ABO-incompatible renal transplantation were satisfactory, and the use of immunoadsorption columns could effectively deplete antibody titers. Glycosorb columns were more efficient than Adsopak columns. Graft survival was better with Glycosorb. Posttransplant infections were a major cause of mortality.

Indexed as

ABO-incompatible transplantationAdsopakGlycosorbImmunoadsorption columns

Identifiers

PMID33487860
PMCPMC7809516
OpenAlexW2996512505

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.