Evidence map›Paper›PMID 33485515›Full record

ArticleMedical engineering & physics2021

Design and analysis of a compliant 3D printed energy harvester housing for knee implants.

Geofrey Yamomo, Nabid Hossain, Shahrzad Towfighian, Ryan Willing

Open access · greenAbstract read
In one paragraph

Article in Medical engineering & physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.3field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. The application of impantable sensors in the musculoskeletal system: a review.Frontiers in bioengineering and biotechnology · 2024
    Review
  3. Sensor Technology in Fracture Healing.Indian journal of orthopaedics · 2023
    Review
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Geofrey YamomoThe University of Western Ontario, 1151 Richmond St, London, Ontario N6A 3K7, Canada. Electronic address: gyamomo@uwo.ca.
Nabid HossainBinghamton University, 4400 Vestal Pkwy E, Binghamton, New York 13902, USA.
Shahrzad TowfighianBinghamton University, 4400 Vestal Pkwy E, Binghamton, New York 13902, USA.
Ryan WillingThe University of Western Ontario, 1151 Richmond St, London, Ontario N6A 3K7, Canada.
Binghamton University · USWestern University · CA

Funding

An implantable self-powered load sensor for total knee replacement health monitoringR21AR068572 · NIAMS · STATE UNIVERSITY OF NY,BINGHAMTON · PI SALMAN, EMRE, TOWFIGHIAN, SHAHRZAD · 2017 to 2018
$349k
NIAMS NIH HHS R21 AR068572
6 · The paper itself

Abstract

Instrumented implants have the potential to detect abnormal loading patterns which could be deleterious to implant longevity, indicating a need for intervention which could reduce the need for more complicated revision surgeries. Reliably powering such devices has been one obstacle preventing widespread usage of instrumented implants in clinical populations. This study presents a 3D-printed titanium interpositional device designed to integrate triboelectric generators (TEGs) into a commercially available total knee replacement (TKR). The device's stiffness, durability, and efficacy as a TEG housing were determined. Surprisingly, the stiffness of the 3D printed prototype was 73% less than what was calculated in a corresponding computational model, and under long-term durability testing failed after approximately 30,000 cycles of simulated gait loading. Under cyclical compressive loading, TEGs embedded in the device were able to generate 10.05 μW of power which is sufficient to run the frontend electronics for a load measurement system. The stiffness discrepancy between the computational and experimental models and the premature fatigue failure are suspected to be a result of internal porosity, unfused material and surface roughness of the 3D printed metal. Further refinements in design and manufacturing of the compliant device are required to improve its durability and TEG power output.

Indexed as

HousingKnee ProsthesisHumansPorosityPrinting, Three-DimensionalTitaniumTitaniumAdditive manufacturingEnergy harvestingLoad SensorTKRTriboelectric

Identifiers

PMID33485515
PMCPMC7882424
OpenAlexW2995416057

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked