Evidence map›Paper›PMID 33484400›Full record

ArticleRadiological physics and technology2021

Development of a transparent and flexible patient-specific bolus for total scalp irradiation.

Noriaki Muramatsu, Satoshi Ito, Masahiro Hanmura, Tetsuo Nishimura

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Application of 3D printing for personalized boluses in radiotherapy: a systematic review.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2025
    Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Noriaki MuramatsuRadiation and Proton Therapy Center, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-cho, Sunto-gun, Shizuoka, 411-8777, Japan. n.muramatsu@scchr.jp.
Satoshi ItoRadiation and Proton Therapy Center, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-cho, Sunto-gun, Shizuoka, 411-8777, Japan.
Masahiro HanmuraRadiation and Proton Therapy Center, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-cho, Sunto-gun, Shizuoka, 411-8777, Japan.
Tetsuo NishimuraRadiation and Proton Therapy Center, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi-cho, Sunto-gun, Shizuoka, 411-8777, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A commercially available flat bolus (commercial bolus) would not fully fit the irregular surfaces of the scalp. We developed a transparent and flexible material with good fitting properties, analyzed its physical characteristics, and evaluated the clinical feasibility of the bolus fabricated using a three-dimensional (3D) printer (3D bolus). To evaluate the physical characteristics of the new material, treatment plans with virtual, 3D, and commercial boluses were created for water-equivalent phantoms using a radiation treatment planning system (RTPS). Using a head phantom and the dose volume histogram calculated with RTPS, dose distributions for total scalp irradiation were compared between the three treatment plans. To evaluate the clinical feasibility, the fitness and reproducibility of the 3D bolus were compared with the head phantom and clinical cases using dice similarity coefficient (DSC) measurements. A good agreement was observed between the percentage depth dose (PDD) curves for the virtual, 3D, and commercial boluses. The homogeneity indexes of the planning target volume (PTV) for the 3D and commercial boluses were 0.083 and 0.153, respectively, proving that the former achieved a better dose uniformity of PTV than the latter. Good fitness and reproducibility with the 3D bolus were observed in both the head phantom and two clinical cases, with mean DSC values of 0.854, 0.829, and 0.843, respectively. These results successfully demonstrated and verified the utility of the 3D bolus for total scalp irradiation.

Indexed as

Radiotherapy Planning, Computer-AssistedScalpHumansPhantoms, ImagingPrinting, Three-DimensionalRadiotherapy DosageReproducibility of Results3D bolus3D printerCommercial bolusHead phantomTotal scalp irradiation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked