ArticlePediatric cardiology2021
Inferior Vena Cava Collapsibility Index to Assess Central Venous Pressure in Perioperative Period Following Cardiac Surgery in Children.
Article in Pediatric cardiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Development and validation of a proposed rule for estimating central venous pressure from inferior vena cava dynamics: a clinical prediction model study.Journal of anesthesia, analgesia and critical care · 2026Article
- Correlation between ultrasound-measured inferior vena cava diameter and peripherally inserted central catheter measured central venous pressure in low birth weight infants.American journal of translational research · 2025Article
- Hepatic vein Doppler ultrasound to estimate central venous pressure in mechanically ventilated children.European journal of pediatrics · 2024Article
- Echocardiographic estimation of pulmonary arterial and right atrial pressures in children with congenital heart disease: a comprehensive prospective study and introduction of novel equations.Journal of cardiovascular imaging · 2024Article
- Usefulness of Non-Invasive Parameters (Inferior Vena Cava Diameter, Inferior Vena Cava Collapsibility, Inferior Vena Cava-Aortic Ratio) for Hemodynamic Monitoring in Critically Ill Children: A Systematic Review.Medical devices (Auckland, N.Z.) · 2024Review
- Diagnostic Utility of Point-of-Care Ultrasound in the Pediatric Cardiac Intensive Care Unit.Current treatment options in pediatrics · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The inferior vena cava collapsibility index (IVCCI) is an ultrasound method used to assess central venous pressure (CVP). Our objective was to evaluate the correlation between IVCCI and CVP in children during the early period following surgery for congenital heart disease (CHD). Prospective study performed in a single tertiary care center. Patients ≤ 18 years old, who underwent cardiopulmonary bypass surgery for CHD, were enrolled. Ultrasound images of the inferior vena cava (IVC) were obtained at two time points; the first was within 2 h of arrival to the CICU and the second was 12-18 h from the first measurement. CVP measured by catheter placed during surgery was recorded within minutes of performing ultrasound. Maximum and minimum IVC diameters were measured by 2D images and M mode method. Seventy patients (47.1% males), with median age 7 months (IQR 4-47 months) and weight 6.9 kg (IQR 4.8-13.5 kg), were evaluated. The 2D IVCCI had inverse correlation with CVP in patients breathing spontaneously; r = - 0.76 (p < 0.01) and r = - 0.73 (p < 0.01), during the first and second measurements, respectively. The 2D IVCCI ≤ 0.24 had sensitivity, specificity, and negative predictive value of 94%, 79%, and 88.9% , respectively, to detect CVP ≥ 10 mmHg. No correlation was found between IVCCI and CVP during positive pressure ventilation. There is a significant inverse correlation between 2D IVCCI and CVP in spontaneously breathing children after surgery for CHD. Use of 2D IVCCI for monitoring CVP could reduce the frequency and duration of CVP catheters and their inherent complications.
Indexed as
Identifiers
33481045What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.