Evidence map›Paper›PMID 33475960›Full record

ArticlePhysical and engineering sciences in medicine2021

Dependence of the heating effect on tissue absorption coefficient during corneal reshaping using different UV lasers: A numerical study.

Ibrahim Abdelhalim, Omnia Hamdy, Aziza Ahmed Hassan, Salah Hassab Elnaby

Abstract read
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ibrahim AbdelhalimDepartment of Engineering Applications of Laser, National Institute of Laser Enhanced Sciences, Cairo University, Giza, 12613, Egypt.
Omnia HamdyDepartment of Engineering Applications of Laser, National Institute of Laser Enhanced Sciences, Cairo University, Giza, 12613, Egypt. omnia@niles.edu.eg.ORCID http://orcid.org/0000-0002-8662-1451
Aziza Ahmed HassanMedical Applications of Laser Dept., National Institute of Laser Enhanced Sciences, Cairo University, Giza, 12613, Egypt.
Salah Hassab ElnabyDepartment of Engineering Applications of Laser, National Institute of Laser Enhanced Sciences, Cairo University, Giza, 12613, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Corneal reshaping using laser ablation effect is a well-known ophthalmologic operation implemented to correct many vision disorders. UV pulsed lasers are utilized in this surgery due to their high absorption in corneal tissue without affecting the other parts of the eye. Ideally ablation may not be associated with heat transport, since high temperature is the enemy of soft tissues. However, the thermal effect of this procedure can cause tissue damage if the temperature rises above the safety level without appropriate handling. In the present study, we try to find the trade-off between efficient ablation and minimal temperature rise. So the thermal effect on the corneal tissue after applying five UV wavelengths; 193, 210, 213, 223 and 248 nm has been simulated and investigated by solving Penne's bio-heat transfer equation using the finite element method. A 3D model of the human cornea is constructed using COMSOL Multiphysics computer software and the temperature rise is determined at the end of the laser pulse. The same spot size and pulse duration are used for each wavelength. While the absorption coefficient of the corneal tissue is the only variable as it is a wavelength dependent. The proposed results show that, the heating effect is directly proportional to the absorption coefficient. The highest recorded temperature was 259 °C at 193 nm, while, the minimum value was (70.1 °C) recorded at 248 nm at which the cornea has the lowest absorption coefficient.

Indexed as

CorneaHeatingHumansLasersLightTemperatureAblationCorneaLASIKUV lasers

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.