ArticleJournal of medical case reports2021
The usefulness of measuring the anion gap in diagnosing metformin-associated lactic acidosis: a case series.
Article in Journal of medical case reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMetformin-associated lactic acidosis (MALA) is a widely documented adverse event of metformin. Despite being considered one of the main causes of metabolic acidosis, the association between an anion gap and MALA diagnosis is still uncertain. CASE PRESENTATION: Cases involving six Caucasian patients with suspected MALA who were admitted to the emergency department were analysed. All these patients presented with pH values < 7.35, lactate levels > 2 mmol/L, and estimated glomerular filtration < 30 mL/min. Metformin plasma concentrations were > 2.5 mg/L in all the patients. The highest metformin concentrations were not found in the patients with the highest lactate levels. The anion gap values ranged from 12.3 to 39.3, with only two patients exhibiting values > 14.
conclusionsIn patients with MALA, there is a significant variability in the anion gap values, which is not related to the level of metformin accumulation, and therefore, it is doubtful whether measuring anion gaps is useful as an approach for MALA diagnosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.