Evidence map›Paper›PMID 33471262›Full record

ArticleRadiological physics and technology2021

Optimal acceleration factor for image acquisition in turbo spin echo: diffusion-weighted imaging with compressed sensing.

Hiroyuki Takashima, Mitsuhiro Nakanishi, Rui Imamura, Yoshihiro Akatsuka, Hiroshi Nagahama, Izaya Ogon

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hiroyuki TakashimaDivision of Radiology and Nuclear Medicine, Sapporo Medical University Hospital, Sapporo, Japan. takashima@sapmed.ac.jp.ORCID http://orcid.org/0000-0003-1077-9188
Mitsuhiro NakanishiDivision of Radiology and Nuclear Medicine, Sapporo Medical University Hospital, Sapporo, Japan.
Rui ImamuraDivision of Radiology and Nuclear Medicine, Sapporo Medical University Hospital, Sapporo, Japan.
Yoshihiro AkatsukaDivision of Radiology and Nuclear Medicine, Sapporo Medical University Hospital, Sapporo, Japan.
Hiroshi NagahamaDivision of Radiology and Nuclear Medicine, Sapporo Medical University Hospital, Sapporo, Japan.
Izaya OgonDepartment of Orthopedic Surgery, Sapporo Medical University School of Medicine, Sapporo, Japan.

Funding

JSPS KAKENHI 18K16667
6 · The paper itself

Abstract

In this study, the change in the image quality and apparent diffusion coefficient (ADC) with increase in the acceleration factor (AF) was analyzed and the most optimal AF was determined to reduce the scan time while preserving the image quality. The AF was changed from 2 to 20 in the MR acquisitions. The similarities between the accelerated and reference images were determined based on the structural similarity (SSIM) index for DWI image and coefficient of variation (%CV) for ADC. The SSIM index decreased significantly when the AF ≥ 8 compared with when the AF = 2 (p < 0.05). In the reference image, the %CV of the ADC increased significantly when the AF ≥ 10 (p < 0.01). In conclusion, a remarkable decrease in the image quality and ADC was observed when the AF was > 8. Thus, an AF < 8 would be optimal for reducing the scan time while preserving the image quality.

Indexed as

AccelerationDiffusion Magnetic Resonance ImagingReproducibility of ResultsAcceleration factorCompressed sensingTurbo spin echo diffusion-weighted image