Evidence map›Paper›PMID 33468154›Full record

ArticleJournal of translational medicine2021

Accuracy of the end-expiratory lung volume measured by the modified nitrogen washout/washin technique: a bench study.

Joana Berger-Estilita, Matthias Haenggi, Daniel Ott, David Berger

Open access · goldAbstract read
In one paragraph

Article in Journal of translational medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Joana Berger-EstilitaDepartment of Anaesthesia and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland. joana.berger-estilita@insel.ch.ORCID 0000-0002-8695-4264
Matthias HaenggiDepartment of Intensive Care Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Daniel OttDepartment of Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
David BergerDepartment of Intensive Care Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
University of Bern · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe functional residual capacity (FRC) determines the oxygenating capacity of the lung and is heavily affected in the clinical context of the acute respiratory distress syndrome. Nitrogen-wash-in/wash-out methods have been used to measure FRC. These methods have rarely been validated against exactly known volumes. The aim of the study was to assess the accuracy and precision of the N

methodsWe conducted a diagnostic bench study in the Intensive Care Unit and Radiology Department of a tertiary hospital in Switzerland. Using a fully controllable high fidelity lung simulator (TestChest®), we set the functional residual capacity at 1500 ml, 2000 ml and 2500 ml and connected to the GE Carestation respirator, which includes the nitrogen washout/washin technique (INview™ tool). FRC was then set to vary by different levels of PEEP (5, 8, 12 and 15 cmH

resultsOne hundred and thirty-five nitrogen-wash-in/wash-out measurements were taken at three levels of F

conclusionsWe conclude that the TestChest® simulator is an accurate simulation tool, concerning the simulation of lung volumes. The nitrogen wash-in/wash out method correlated positively with FRC changes, despite a relatively large bias in absolute measurements. The reference volumes in the lung simulator verified with CT volumetry were very close to their expected values. The reason for the bias could not be determined.

Indexed as

Positive-Pressure RespirationRespiratory Distress SyndromeFunctional Residual CapacityHumansLung Volume MeasurementsNitrogenNitrogenEnd-expiratory lung volumeFunctional residual capacityWashin/washout technique

Identifiers

PMID33468154
PMCPMC7815189
OpenAlexW3121546065

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked