Evidence map›Paper›PMID 33465155›Full record

ArticlePloS one2021

Simultaneous ventilation in the Covid-19 pandemic. A bench study.

Claude Guérin, Martin Cour, Neven Stevic, Florian Degivry, Erwan L'Her, Bruno Louis, Laurent Argaud

Abstract readComparative Study
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Claude GuérinMédecine Intensive-Réanimation, Hospices Civils de Lyon, Groupement Hospitalier Centre, Hôpital Edouard Herriot, Lyon, France.ORCID 0000-0003-4700-6672
Martin CourMédecine Intensive-Réanimation, Hospices Civils de Lyon, Groupement Hospitalier Centre, Hôpital Edouard Herriot, Lyon, France.
Neven StevicMédecine Intensive-Réanimation, Hospices Civils de Lyon, Groupement Hospitalier Centre, Hôpital Edouard Herriot, Lyon, France.
Florian DegivryMédecine Intensive-Réanimation, Hospices Civils de Lyon, Groupement Hospitalier Centre, Hôpital Edouard Herriot, Lyon, France.
Erwan L'HerMédecine Intensive-Réanimation, CHU de Brest, Brest, France.
Bruno LouisInstitut Mondor de Recherches Biomédicales, INSERM UMR 955 Eq13-CNRS ERL 7000, Créteil, France.
Laurent ArgaudMédecine Intensive-Réanimation, Hospices Civils de Lyon, Groupement Hospitalier Centre, Hôpital Edouard Herriot, Lyon, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

COVID-19 pandemic sets the healthcare system to a shortage of ventilators. We aimed at assessing tidal volume (VT) delivery and air recirculation during expiration when one ventilator is divided into 2 test-lungs. The study was performed in a research laboratory in a medical ICU of a University hospital. An ICU (V500) and a lower-level ventilator (Elisée 350) were attached to two test-lungs (QuickLung) through a dedicated flow-splitter. A 50 mL/cmH2O Compliance (C) and 5 cmH2O/L/s Resistance (R) were set in both A and B test-lungs (A C50R5 / B C50R5, step1), A C50-R20 / B C20-R20 (step 2), A C20-R20 / B C10-R20 (step 3), and A C50-R20 / B C20-R5 (step 4). Each ventilator was set in volume and pressure control mode to deliver 800mL VT. We assessed VT from a pneumotachograph placed immediately before each lung, pendelluft air, and expiratory resistance (circuit and valve). Values are median (1st-3rd quartiles) and compared between ventilators by non-parametric tests. Between Elisée 350 and V500 in volume control VT in A/B test- lungs were 381/387 vs. 412/433 mL in step 1, 501/270 vs. 492/370 mL in step 2, 509/237 vs. 496/332 mL in step 3, and 496/281 vs. 480/329 mL in step 4. In pressure control the corresponding values were 373/336 vs. 430/414 mL, 416/185 vs. 322/234 mL, 193/108 vs. 176/ 92 mL and 422/201 vs. 481/329mL, respectively (P<0.001 between ventilators at each step for each volume). Pendelluft air volume ranged between 0.7 to 37.8 ml and negatively correlated with expiratory resistance in steps 2 and 3. The lower-level ventilator performed closely to the ICU ventilator. In the clinical setting, these findings suggest that, due to dependence of VT to C, pressure control should be preferred to maintain adequate VT at least in one patient when C and/or R changes abruptly and monitoring of VT should be done carefully. Increasing expiratory resistance should reduce pendelluft volume.

Indexed as

COVID-19FemaleHumansLung ComplianceLung Volume MeasurementsMaleMaximal Respiratory PressuresRespiration, ArtificialVentilators, Mechanical

Identifiers

PMID33465155
PMCPMC7815120

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.