Evidence map›Paper›PMID 33463421›Full record

ArticleJoint diseases and related surgery2021

The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis.

Serhat Durusoy, Kerim Öner, Alaattin Özer, Hüseyin Fatih Sevinç

Abstract read
In one paragraph

Article in Joint diseases and related surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Pediatric infrafossal fracture of the humerus: A case series.Joint diseases and related surgery · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Serhat DurusoyYozgat Bozok Üniversitesi Tıp Fakültesi Eğitim ve Araştırma Hastanesi, 66100 Yozgat, Türkiye. serquat@gmail.com.
Kerim Öner
Alaattin Özer
Hüseyin Fatih Sevinç

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study aims to investigate the effects of the angles created by the Kirschner wires (K-wires), which are applied in the percutaneous fixation of supracondylar humerus fractures with cross K-wire, with the fracture line on fracture stabilization. PATIENTS AND

methodsThe study was conducted on distal humerus fracture models. Medial and lateral K-wires were placed in the fracture models. The angle between the fracture line and the K-wire inserted from medial was represented by alpha (α), while the angle between the fracture line and the K-wires inserted from lateral was represented by beta (β). A combination of various angles (30°, 45°, and 60°) was used in each model, where no two models had the same combination of α and β, resulting in nine different wire configurations. The simulation program was used to simulate the effects of forces, which were applied on rotation, flexion and extension directions, on these models. We measured and compared the stress on the wires and the displacement of fractures under different force configurations.

resultsWhen the force was applied in the counterclockwise direction, the stresses were 58 megapascal (MPa) on medial K-wire, 24 MPa on lower lateral K-wire, and 45 MPa on upper lateral K-wire in (45°, 45°) wire configuration. When the force was applied in the clockwise direction, the stresses were 57 MPa on medial K-wire, 23 MPa on lower lateral K-wire, and 45 MPa on upper lateral K-wire in (45°, 45°) wire configuration. In all models, the increased α and β angles were translated into the decreased stress on K-wires at the fracture level and decreased displacement under rotational deforming forces. Despite having generally lower fracture displacement, the increased α and β angles led to variable changes in the stress on K-wires against flexion and extension forces.

conclusionIn supracondylar humerus fractures, increasing the insertion angle of both medial and lateral K-wires augments stabilization and reduces displacement, particularly against rotational deforming forces.

Indexed as

Bone WiresHumeral FracturesComputer SimulationFinite Element AnalysisFracture DislocationFracture Fixation, InternalHumansMechanical Phenomena

Identifiers

PMID33463421
PMCPMC8073442

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.