ArticleJoint diseases and related surgery2021
Combined palmar and dorsal plating of four-part distal radius fractures: Our clinical and radiological results.
Article in Joint diseases and related surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 11 citations in OpenAlex.
- Dual Plating and Dorsal Bridge Plating for Comminuted Distal Radius Fractures: A Systematic Review.Journal of clinical medicine · 2026Review
- Is Dorsal Vertical Double Plating an Effective Alternative to Volar Plating for Distal Radius Fractures With Dorsal Collapse?Orthopaedic surgery · 2026Article
- A new distal radius fracture classification depending on the specific fragments through machine learning clustering method.BMC musculoskeletal disorders · 2024Article
- Treatment Effectiveness of Volar Plates in Distal Radius Dorsal Rim Fractures.Revista brasileira de ortopedia · 2024Article
- Does skyline view prevent extensor tendon pathologies during volar plating of distal radius? An ultrasonographic evaluation.Joint diseases and related surgery · 2023Article
- Residual dorsal displacement following surgery in distal radial fractures: A cause for trouble?European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2023Article
- COMBINED PLATE VERSUS EXTERNAL FIXATION FOR DISTAL RADIUS FRACTURES.Acta ortopedica brasileira · 2023Article
- Is tendinitis in volar plating related to the dorsally protruding screw length and its compartment?Joint diseases and related surgery · 2023Article
- The external fixation can be a good alternative to plate-screw treatment in the surgical treatment of bilateral distal radius fractures: A retrospective cohort study.Joint diseases and related surgery · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThis study aims to investigate the radiological and clinical outcomes of four-part intraarticular distal radius fractures treated with a volar anatomically locked plate and 2 mm low-profile plates using both the volar and dorsal approaches. PATIENTS AND
methodsThis retrospective study included 20 patients (8 males, 12 females; mean age 47±12.1; range, 25 to 67 years) who received open reduction and internal fixation with combined volar and dorsal plating to treat complex four-part distal radius fractures (shaft, radial styloid area, dorsal medial facet, volar medial facet) between May 2016 and January 2019. According to Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification, all fractures were 2R3-C3. According to Melone classification, one fracture was type 1, seven fractures were type 2a, three were type 2b, three were type 3 and six were type 4. The mean follow-up time was 21±7.5 (range, 12 to 36) months.
resultsUnion was achieved in all fractures. The mean tourniquet time was 103±12 (range, 90 to 130) minutes. The mean Disabilities of the Arm, Shoulder, and Hand questionnaire score was 10±9, and the mean Visual Analog Scale score was 2.1±0.9. According to Mayo wrist score, five patients had excellent, six had good, six had satisfactory and three had poor results. The mean grip strength was 25.2±9.2 (range, 15 to 40) kg and 78% of opposite side. Mean wrist flexion was 48.7°±15.3° (range, 30° to 80°), extension was 52.2°±17.2° (range, 25° to 80°), radio-ulnar deviation arc was 40.7°±6.9° (range, 30° to 55°), and mean forearm rotation arc was 152.3°±11° (range, 130° to 170°).
conclusionPlating method with a dual approach may be an alternative for four-part intraarticular distal radius fractures given its early mobility advantage and satisfactory functional and radiological results.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.