Evaluating the repeatability and set-up sensitivity of a large field of view distortion phantom and software for magnetic resonance-only radiotherapy.

Jonathan Wyatt, Stephen Hedley, Emily Johnstone, Richard Speight, Charles Kelly, Ann Henry, Susan Short, Louise Murray, David Sebag-Montefiore, Hazel McCallum

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Imaging science and development in modern high-precision radiotherapy.Physics and imaging in radiation oncology · 2019
    Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jonathan WyattNorthern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK.
Stephen HedleyNorthern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK.
Emily JohnstoneLeeds Institute of Cancer and Pathology, University of Leeds, Leeds, UK.
Richard SpeightLeeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Charles KellyNorthern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK.
Ann HenryLeeds Institute of Cancer and Pathology, University of Leeds, Leeds, UK.
Susan ShortLeeds Institute of Cancer and Pathology, University of Leeds, Leeds, UK.
Louise MurrayLeeds Institute of Cancer and Pathology, University of Leeds, Leeds, UK.
David Sebag-MontefioreLeeds Institute of Cancer and Pathology, University of Leeds, Leeds, UK.
Hazel McCallumNorthern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK.

Funding

Cancer Research UK 21993
6 · The paper itself

Abstract

background and purposeMagnetic Resonance (MR)-only radiotherapy requires geometrically accurate MR images over the full scanner Field of View (FoV). This study aimed to investigate the repeatability of distortion measurements made using a commercial large FoV phantom and analysis software and the sensitivity of these measurements to small set-up errors. MATERIALS AND

methodsGeometric distortion was measured using a commercial phantom and software with 2D and 3D acquisition sequences on three different MR scanners. Two sets of repeatability measurements were made: three scans acquired without moving the phantom between scans (single set-up) and five scans acquired with the phantom re-set up in between each scan (repeated set-up). The set-up sensitivity was assessed by scanning the phantom with an intentional 1 mm lateral offset and independently an intentional 1° rotation.

resultsThe mean standard deviation of distortion for all phantom markers for the repeated set-up scans was

conclusionsGeometric distortion measurements using a commercial phantom and associated software appear repeatable, although with some sensitivity to set-up errors. This suggests the phantom and software are appropriate for commissioning a MR-only radiotherapy workflow.

Indexed as

Geometric distortionMagnetic resonance imagingMR-only radiotherapy planningRadiotherapy

Identifiers

PMID33458386
PMCPMC7807542

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.