ArticlePhysics and imaging in radiation oncology2020
Evaluation of multi-institutional end-to-end testing for post-operative spine stereotactic body radiation therapy.
Article in Physics and imaging in radiation oncology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Comparison of Titanium and Carbon Fiber-Reinforced Polyetheretherketone Spinal Implants in Postoperative Spine Stereotactic Body Radiation Therapy: A Comprehensive Review of Current Evidence and Future Perspectives.Advances in radiation oncology · 2026Review
- The transformative role of SBRT in the management of spinal metastases.Nature reviews. Clinical oncology · 2026Review
- Clinical Application of Patient-Specific Bolus Based on Molding and Casting Method in Radiotherapy.Journal of clinical medicine · 2025Article
- Evaluation of computed tomography artefacts of carbon-fiber and titanium implants in patients with spinal oligometastatic disease undergoing stereotactic ablative radiotherapy.Scientific reports · 2024Article
- Stereotactic body radiotherapy for spine metastases: a review of 24 Gy in 2 daily fractions.Journal of neuro-oncology · 2023Review
- Radiation myelopathy following stereotactic body radiation therapy for spine metastases.Journal of neuro-oncology · 2022Review
- Accuracy of the doses computed by the Eclipse treatment planning system near and inside metal elements.Scientific reports · 2022Article
- Evaluation of the Treatment Planning and Delivery for Hip Implant Cases on Tomotherapy.Journal of medical physicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposePost-operative spine stereotactic body radiation therapy (SBRT) represents a significant challenge as there are many restrictions on beam geometry to avoid metal hardware as it surrounds the target volume. In this study, an international multi-institutional end-to-end test using an in-house spine phantom was developed and executed. The aim was to evaluate the impact of titanium spine hardware on planned and delivered dose for post-operative spine SBRT. MATERIALS AND
methodsFive centers performed simulation, planning and irradiation of the spine phantom, with/without titanium metal hardware (MB/B), following our pre-specified protocol. The doses were calculated using the centers' treatment planning system (TPS) and measured with radiophotoluminescent glass dosimeters (RPLDs) embedded within each phantom.
resultsThe dose differences between the RPLD measured and calculated doses in the target region were within ± 5% for both phantoms studied. Differences greater than 5% were observed for the spinal cord and the out-of-the target regions due to steeper dose gradient regions that are created in these plans. Dose measurements within ± 3% were observed between RPLDs that were embedded in MB and B inserts. For the spinal cord and the out-of-target regions surrounded by metal hardware, the dose measured using RPLDs was within 3% different near the titanium screws compared to the dose measured near only the metal rods.
conclusionWe have successfully performed the first multi-institutional end-to-end dose analysis using an in-house phantom built specifically for post-operative spine SBRT. The differences observed between the measured and planned doses in the presence of metal hardware were clinically insignificant.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials