Evidence map›Paper›PMID 33458345›Full record

ArticlePhysics and imaging in radiation oncology2020

Evaluation of multi-institutional end-to-end testing for post-operative spine stereotactic body radiation therapy.

Tomohisa Furuya, Young K Lee, Ben R Archibald-Heeren, Mikel Byrne, Bruno Bosco, Jun H Phua, Hidetoshi Shimizu, Shimpei Hashimoto, Hiroshi Tanaka, Arjun Sahgal and 1 more

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Tomohisa FuruyaDepartment of Radiology, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, 1138677 Tokyo, Japan.
Young K LeeDepartment of Radiation Oncology, Sunnybrook Odette Cancer Center, University of Toronto, M4N 3M5 Toronto, Ontario, Canada.
Ben R Archibald-HeerenRadiation Oncology Centres, Sydney Adventist Hospital, Wahroonga, NSW 2076, Australia.
Mikel ByrneRadiation Oncology Centres, Sydney Adventist Hospital, Wahroonga, NSW 2076, Australia.
Bruno BoscoRadiation Oncology Centres, Sydney Adventist Hospital, Wahroonga, NSW 2076, Australia.
Jun H PhuaDepartment of Radiation Oncology, National Cancer Center Singapore, 169610 Singapore, Singapore.
Hidetoshi ShimizuDepartment of Radiation Oncology, Aichi Cancer Center Hospital, 4648681 Aichi, Japan.
Shimpei HashimotoDepartment of Radiology, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, 1138677 Tokyo, Japan.
Hiroshi TanakaDepartment of Radiation Oncology, Aichi Cancer Center Hospital, 4648681 Aichi, Japan.
Arjun SahgalDepartment of Radiation Oncology, Sunnybrook Odette Cancer Center, University of Toronto, M4N 3M5 Toronto, Ontario, Canada.
Katsuyuki KarasawaDepartment of Radiology, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, 1138677 Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposePost-operative spine stereotactic body radiation therapy (SBRT) represents a significant challenge as there are many restrictions on beam geometry to avoid metal hardware as it surrounds the target volume. In this study, an international multi-institutional end-to-end test using an in-house spine phantom was developed and executed. The aim was to evaluate the impact of titanium spine hardware on planned and delivered dose for post-operative spine SBRT. MATERIALS AND

methodsFive centers performed simulation, planning and irradiation of the spine phantom, with/without titanium metal hardware (MB/B), following our pre-specified protocol. The doses were calculated using the centers' treatment planning system (TPS) and measured with radiophotoluminescent glass dosimeters (RPLDs) embedded within each phantom.

resultsThe dose differences between the RPLD measured and calculated doses in the target region were within ± 5% for both phantoms studied. Differences greater than 5% were observed for the spinal cord and the out-of-the target regions due to steeper dose gradient regions that are created in these plans. Dose measurements within ± 3% were observed between RPLDs that were embedded in MB and B inserts. For the spinal cord and the out-of-target regions surrounded by metal hardware, the dose measured using RPLDs was within 3% different near the titanium screws compared to the dose measured near only the metal rods.

conclusionWe have successfully performed the first multi-institutional end-to-end dose analysis using an in-house phantom built specifically for post-operative spine SBRT. The differences observed between the measured and planned doses in the presence of metal hardware were clinically insignificant.

Indexed as

End-to-end testImpact of metal hardwareMulti-institutional phantom studyPost-operative spine SBRTSABR

Identifiers

PMID33458345
PMCPMC7807765

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.