ArticlePhysics and imaging in radiation oncology2020
Early clinical experience with a total body irradiation technique using field-in-field beams and on-line image guidance.
Article in Physics and imaging in radiation oncology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 10 citations in OpenAlex.
- Commissioning and performance evaluation of commercially available mobile imager for image guided total body irradiation.Journal of applied clinical medical physics · 2023Article
- Optimised conformal total body irradiation: a heterogeneous practice, so where next?The British journal of radiology · 2023Review
- Improving total body irradiation with a dedicated couch and 3D-printed patient-specific lung blocks: A feasibility study.Frontiers in oncology · 2022Article
- Total Body Irradiation in Haematopoietic Stem Cell Transplantation for Paediatric Acute Lymphoblastic Leukaemia: Review of the Literature and Future Directions.Frontiers in pediatrics · 2021Review
- Evaluation of Surface Dose and Commissioning of Compensator-Based Total Body Irradiation.Journal of medical physicsArticle
- A Phantom Study on Feasibility of Manual Field-in-Field Clinical Implementation for Total Body Irradiation and Comparison of Midplane Dose with Different Bilateral TBI Techniques.Journal of medical physicsArticle
- Validation of Treatment Planning Systems based on Dose Calculation Accuracy for Extended SSD Total Body Irradiation with and without Beam Spoiler.Journal of medical physicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeTotal body irradiation (TBI) is a treatment used in the conditioning of patients prior to hematopoietic stem cell transplantation. We developed an extended-distance TBI technique using a conventional linac with multi-leaf collimator to deliver a homogeneous dose, and spare critical organs. MATERIALS AND
methodsPatients were treated either in lateral recumbent or in supine position depending on the dose level. A conventional linac was used with the patient midline at 350 cm from the beam source. A series of beams was prepared manually using a 3D treatment planning system (TPS) aiming to improve dose homogeneity, spare the organs at risk and facilitate accurate patient positioning. An optimized dose calculation model for extended-distance treatments was developed using phantom measurements. During treatment, in-vivo dosimetry was performed using electronic dosimeters, and accurate positioning was verified using a mobile megavoltage imager. We analyzed dose volume histogram parameters for 19 patients, and in-vivo measurements for 46 delivered treatment fractions.
resultsOptimization of the dose calculation model for TBI improved dose calculation by 2.1% at the beam axis, and 17% at the field edge. Treatment planning dose objectives and constraints were met for 16 of 19 patients. Results of in-vivo dosimetry were within the set limitations (±10%) with mean deviations of 3.7% posterior of the lungs and 0.6% for the abdomen.
conclusionsWe developed a TBI treatment technique using a conventional linac and TPS that can reliably be used in the conditioning regimen of patients prior to stem cell transplantation.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.