Evidence map›Paper›PMID 33458292›Full record

ArticlePhysics and imaging in radiation oncology2019

Clinical experience with lung-specific electromagnetic transponders for real-time tumor tracking in lung stereotactic body radiotherapy.

Maud Jaccard, Ambroise Champion, Angèle Dubouloz, Cristina Picardi, Jérôme Plojoux, Paola Soccal, Raymond Miralbell, Giovanna Dipasquale, Francesca Caparrotti

Open access · goldAbstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 16 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 2 countries.

Maud JaccardDepartment of Radiation Oncology, Geneva University Hospital, 53 Av. de la Roseraie, 1205 Geneva, Switzerland.
Ambroise ChampionDepartment of Radiation Oncology, Geneva University Hospital, 53 Av. de la Roseraie, 1205 Geneva, Switzerland.
Angèle DuboulozDepartment of Radiation Oncology, Geneva University Hospital, 53 Av. de la Roseraie, 1205 Geneva, Switzerland.
Cristina PicardiDepartment of Radiation Oncology, Geneva University Hospital, 53 Av. de la Roseraie, 1205 Geneva, Switzerland.
Jérôme PlojouxDepartment of Pneumology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, 1205 Geneva, Switzerland.
Paola SoccalDepartment of Pneumology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, 1205 Geneva, Switzerland.
Raymond MiralbellDepartment of Radiation Oncology, Geneva University Hospital, 53 Av. de la Roseraie, 1205 Geneva, Switzerland.
Giovanna DipasqualeDepartment of Radiation Oncology, Geneva University Hospital, 53 Av. de la Roseraie, 1205 Geneva, Switzerland.
Francesca CaparrottiDepartment of Radiation Oncology, Geneva University Hospital, 53 Av. de la Roseraie, 1205 Geneva, Switzerland.
University Hospital of Geneva · CHHospital Quirón Teknon · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposesMotion management is crucial for optimal stereotactic body radiotherapy (SBRT) of moving targets. We aimed to describe our clinical experience with real-time tracking of lung-specific electromagnetic transponders (EMTs) for SBRT of early stage non-small cell lung cancer in free-breathing (FB) or deep inspiration breath-hold (DIBH). MATERIAL AND

methodsSeven patients were implanted with EMTs. Simulation for SBRT was performed in FB and in DIBH. We prescribed 60 Gy in 3, 5 or 8 fractions to the tumor and delivered SBRT with volumetric modulated arcs and a 6 MV flattening filter free photon beam. Patients' setup at the linac was performed using EMT positions and cone-beam CT (CBCT) verification. Four patients were treated in DIBH because of a dosimetric benefit. We analysed patient alignment and treatment delivery parameters using DIBH or FB and EMT real-time tracking.

resultsThere were no complications from the EMT implantation. Visual inspection of CBCT before and/or after SBRT revealed good alignment of structures and EMTs. The median setup time was 9.8 min (range: 4.6-34.1 min) and the median session time was 14.7 min (range: 7.3-36.5 min). EMT positions in lungs remained stable during overall treatment and allowed real-time tracking both in FB and in DIBH SBRT. The treatment beam was gated when EMT centroid position exceeded tolerance thresholds ensuring correct delivery of radiation to the tumor.

conclusionUsing EMTs for real-time tracking of tumor motion during lung SBRT proved to be safe, accurate and easy to integrate clinically for treatments in FB or DIBH.

Indexed as

Deep inspiration breath-holdElectromagnetic transponderIntra-fraction motionLung SBRTReal-time tracking

Identifiers

PMID33458292
PMCPMC7807938
OpenAlexW2991110459

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.