ArticlePhysics and imaging in radiation oncology2019
Development and accuracy evaluation of a single-camera intra-bore surface scanning system for radiotherapy in an O-ring linac.
Article in Physics and imaging in radiation oncology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 14 citations in OpenAlex.
- Surface guided ring gantry radiotherapy in deep inspiration breath hold for breast cancer patients.Journal of applied clinical medical physics · 2024Article
- Reproducibility of surface-based deep inspiration breath-hold technique for lung stereotactic body radiotherapy on a closed-bore gantry linac.Physics and imaging in radiation oncology · 2023Article
- A method for beam's eye view breath-hold monitoring during breast volumetric modulated arc therapy.Physics and imaging in radiation oncology · 2023Article
- Advances and potential of optical surface imaging in radiotherapy.Physics in medicine and biology · 2022Review
- Accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: A phantom study.Journal of applied clinical medical physics · 2022Article
- Surface-guided radiation therapy for breast cancer: more precise positioning.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2021Article
- Intra-fraction motion monitoring during fast modulated radiotherapy delivery in a closed-bore gantry linac.Physics and imaging in radiation oncology · 2021Article
- Recent advanced in Surface Guided Radiation Therapy.Radiation oncology (London, England) · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeCurrent commercial surface scanning systems are not able to monitor patients during radiotherapy fractions in closed-bore linacs during adaptive workflows. In this work a surface scanning system for monitoring in an O-ring linac is proposed. METHODS AND MATERIALS: A depth camera was mounted at the backend of the bore. The acquired surface point cloud was transformed to the linac coordinate system after a cube detection calibration step. The real-time surface was registered using an Iterative Closest Point algorithm to a reference region-of-interest of the body contour from the planning CT and of a depth camera surface acquisition from the first fraction. The positioning accuracy was investigated using anthropomorphic 3D-printed phantoms with embedded markers: a head, hand and breast. To simulate clinically observed positioning errors, each phantom was placed 24 times with 0-10 mm and 0-8° offsets from the planned position. At every position a cone-beam CT (CBCT) was acquired and a surface registration performed. The surface registration error was determined as the difference between the surface registration and the CBCT-to-CT fiducial marker registration.
resultsThe registration errors were (mean ± SD): lat: 0.4 ± 0.8 mm, vert: -0.2 ± 0.2 mm, long: 0.3 ± 0.5 mm and Yaw: -0.2 ± 0.6°, Pitch: 0.4 ± 0.2°, Roll: 0.5 ± 0.8° for the body contour reference, and lat: -0.7 ± 0.7 mm, vert: 0.3 ± 0.2 mm, long: 0.2 ± 0.5 mm and Yaw: -0.5 ± 0.5°, Pitch: 0.1 ± 0.3°, Roll: -0.7 ± 0.7° for the captured surface reference.
conclusionThe proposed single camera intra-bore surface system was capable of accurately detecting phantom displacements and allows intrafraction motion monitoring for surface guided radiotherapy inside the bore of O-ring gantries.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.